Back to Search Start Over

The impact of transvenous cardioverter-defibrillator implantation on quality of life, depression and optimism in dialysis patients: report on the secondary outcome of QOL in the randomized controlled ICD2 trial.

Authors :
Timal, Rohit J.
de Gucht, Veronique
Rotmans, Joris I.
Hensen, Liselotte C. R.
Buiten, Maurits S.
de Bie, Mihaly K.
Putter, Hein
Schalij, Martin J.
Rabelink, Ton J.
Jukema, J. Wouter
Source :
Quality of Life Research. Jun2021, Vol. 30 Issue 6, p1605-1617. 13p. 1 Diagram, 5 Charts, 1 Graph.
Publication Year :
2021

Abstract

Rationale: The impact of prophylactic implantable cardioverter-defibrillator (ICD) implantation on the psychological well-being of patients on dialysis is unknown. Objective: We aimed to identify the effect of primary ICD implantation on quality of life (QoL), mood and dispositional optimism in patients undergoing dialysis. Methods and results: We performed a prespecified subanalysis of the randomized controlled ICD2 trial. In total, 177 patients on chronic dialysis, with an age of 55–81 years, and a left ventricular ejection fraction of ≥ 35%, were included in the per-protocol analysis. Eighty patients received an ICD for primary prevention, and 91 patients received standard care. The Short Form-36 (SF-36), Geriatric Depression Scale-15 (GDS-15), Revised Life Orientation Test (LOT-R) questionnaires were administered prior to ICD implantation (T0), and at 1-year follow-up (T1) to assess QoL, depression and optimism, respectively. The patients were predominantly male (76.0%), with a median age of 67 years. Hemodialysis was the predominant mode of dialysis (70.2%). The GDS-15 score difference (T1 − T0) was 0.5 (2.1) in the ICD group compared with 0.3 (2.2) in the control group (mean difference − 0.3; 95% CI − 1.1 to 0.6; P = 0.58). The LOT-R score difference was − 0.2 (4.1) in the ICD group compared with − 1.5 (4.0) in the control group (mean difference − 1.1 (0.8); 95% CI − 2.6 to 0.4; P = 0.17). The mean difference scores of all subscales of the SF-36 were not significantly different between randomization groups. Conclusions: In our population of patients on dialysis, ICD implantation did not affect QoL, mood or dispositional optimism significantly during 1-year follow-up. Clinical Trial Registration: Unique identifier: ISRCTN20479861. http://www.controlled-trials.com. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09629343
Volume :
30
Issue :
6
Database :
Academic Search Index
Journal :
Quality of Life Research
Publication Type :
Academic Journal
Accession number :
150691903
Full Text :
https://doi.org/10.1007/s11136-020-02744-7