Back to Search Start Over

Non-Contact Ultrasonic Flow Measurement for Small Pipes Based on AlN Piezoelectric Micromachined Ultrasonic Transducer Arrays.

Authors :
Zhu, Ke
Chen, Xuying
Qu, Mengjiao
Yang, Dengfei
Hu, Liang
Xie, Jin
Source :
Journal of Microelectromechanical Systems. Jun2021, Vol. 30 Issue 3, p480-487. 8p.
Publication Year :
2021

Abstract

In this paper, we propose a non-contact ultrasonic liquid flowmeter based on AlN piezoelectric micromachined ultrasonic transducer (PMUT) arrays. Two 10 by 10 PMUT arrays with resonant frequency of 980 kHz in air are mounted outside of a pipe to measure liquid flow without contacting the liquid. An acoustic matching layer is designed to mitigate the loss of sound waves caused by sound reflection. Under excitation of continuous wave, the flow of the liquid can be determined via detecting the phase difference between transmitting and received signals. The measurement range of flow is 0.515 L/min ~ 3.40 L/min and the measurement error is less than 3%. Moreover, an interpolation method is proposed to reduce the signal sampling frequency without obviously affecting the measurement accuracy, which shows potential for further system integration. [2021-0033] [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10577157
Volume :
30
Issue :
3
Database :
Academic Search Index
Journal :
Journal of Microelectromechanical Systems
Publication Type :
Academic Journal
Accession number :
150633360
Full Text :
https://doi.org/10.1109/JMEMS.2021.3066408