Back to Search Start Over

Comparison of liver exposure in CT-guided high-dose rate (HDR) interstitial brachytherapy versus SBRT in hepatocellular carcinoma.

Authors :
Walter, Franziska
Nierer, Lukas
Rottler, Maya
Duque, Anna Sophie
Weingandt, Helmut
Well, Justus
Shpani, Roel
Landry, Guillaume
Seidensticker, Max
Streitparth, Florian
Ricke, Jens
Belka, Claus
Corradini, Stefanie
Source :
Radiation Oncology. 5/6/2021, Vol. 16 Issue 1, p1-10. 10p.
Publication Year :
2021

Abstract

<bold>Background: </bold>In unresectable hepatocellular carcinoma several local ablative treatments are available. Among others, radiation based treatments such as stereotactic body radiotherapy (SBRT) and high-dose rate interstitial brachytherapy (HDR BT) have shown good local control rates.<bold>Methods: </bold>We conducted a dose comparison between actually performed HDR BT versus virtually planned SBRT to evaluate the respective clinically relevant radiation exposure to uninvolved liver tissue. Moreover, dose coverage and conformity indices were assessed.<bold>Results: </bold>Overall, 46 treatment sessions (71 lesions, 38 patients) were evaluated. HDR BT was applied in a single fraction with a dose prescription of 1 × 15 Gy. D98 was 17.9 ± 1.3 Gy, D50 was 41.8 ± 8.1 Gy. The SBRT was planned with a prescribed dose of 3 × 12.5 Gy (65%-Isodose), D98 was 50.7 ± 3.1 Gy, D2 was 57.0 ± 2.3 Gy, and D50 was 55.2 ± 2.3 Gy. Regarding liver exposure Vliver10GyBT was compared to Vliver15.9GySBRT, Vliver16.2GySBRT (EQD2 equivalent doses), and Vliver20GySBRT (clinically relevant dose), all results showed significant differences (p < .001). In a case by case analysis Vliver10GyBT was smaller than Vliver20GySBRT in 38/46 cases (83%). Dmean of the liver was significantly smaller in BT compared to SBRT (p < .001). GTV volume was correlated to the liver exposure and showed an advantage of HDR BT over SBRT in comparison of clinically relevant doses, and for EQD2 equivalent doses. The advantage was more pronounced for greater liver lesions The Conformity Index (CI) was significantly better for BT, while Healthy Tissue Conformity Index (HTCI) and Conformation Number (CN) showed an advantage for SBRT (p < .001).<bold>Conclusion: </bold>HDR BT can be advantageous in respect of sparing of normal liver tissue as compared to SBRT, while providing excellent target conformity. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1748717X
Volume :
16
Issue :
1
Database :
Academic Search Index
Journal :
Radiation Oncology
Publication Type :
Academic Journal
Accession number :
150167475