Small Animal IMRT Using 3D-Printed Compensators.

Authors :
Redler, Gage
Pearson, Erik
Liu, Xinmin
Gertsenshteyn, Inna
Epel, Boris
Pelizzari, Charles
Aydogan, Bulent
Weichselbaum, Ralph
Halpern, Howard J.
Wiersma, Rodney D.
Source :
International Journal of Radiation Oncology, Biology, Physics. Jun2021, Vol. 110 Issue 2, p551-565. 15p.
Publication Year :
2021

Abstract

<bold>Purpose: </bold>Preclinical radiation replicating clinical intensity modulated radiation therapy (IMRT) techniques can provide data translatable to clinical practice. For this work, treatment plans were created for oxygen-guided dose-painting in small animals using inverse-planned IMRT. Spatially varying beam intensities were achieved using 3-dimensional (3D)-printed compensators.<bold>Methods and Materials: </bold>Optimized beam fluence from arbitrary gantry angles was determined using a verified model of the XRAD225Cx treatment beam. Compensators were 3D-printed with varied thickness to provide desired attenuation using copper/polylactic-acid. Spatial resolution capabilities were investigated using printed test-patterns. Following American Association of Physicists in Medicine TG119, a 5-beam IMRT plan was created for a miniaturized (∼1/8th scale) C-shape target. Electron paramagnetic resonance imaging of murine tumor oxygenation guided simultaneous integrated boost (SIB) plans conformally treating tumor to a base dose (Rx1) with boost (Rx2) based on tumor oxygenation. The 3D-printed compensator intensity modulation accuracy and precision was evaluated by individually delivering each field to a phantom containing radiochromic film and subsequent per-field gamma analysis. The methodology was validated end-to-end with composite delivery (incorporating 3D-printed tungsten/polylactic-acid beam trimmers to reduce out-of-field leakage) of the oxygen-guided SIB plan to a phantom containing film and subsequent gamma analysis.<bold>Results: </bold>Resolution test-patterns demonstrate practical printer resolution of ∼0.7 mm, corresponding to 1.0 mm bixels at the isocenter. The miniaturized C-shape plan provides planning target volume coverage (V95% = 95%) with organ sparing (organs at risk Dmax < 50%). The SIB plan to hypoxic tumor demonstrates the utility of this approach (hypoxic tumor V95%,Rx2 = 91.6%, normoxic tumor V95%,Rx1 = 95.7%, normal tissue V100%,Rx1 = 7.1%). The more challenging SIB plan to boost the normoxic tumor rim achieved normoxic tumor V95%,Rx2 = 90.9%, hypoxic tumor V95%,Rx1 = 62.7%, and normal tissue V100%,Rx2 = 5.3%. Average per-field gamma passing rates using 3%/1.0 mm, 3%/0.7 mm, and 3%/0.5 mm criteria were 98.8% ± 2.8%, 96.6% ± 4.1%, and 90.6% ± 5.9%, respectively. Composite delivery of the hypoxia boost plan and gamma analysis (3%/1 mm) gave passing results of 95.3% and 98.1% for the 2 measured orthogonal dose planes.<bold>Conclusions: </bold>This simple and cost-effective approach using 3D-printed compensators for small-animal IMRT provides a methodology enabling preclinical studies that can be readily translated into the clinic. The presented oxygen-guided dose-painting demonstrates that this methodology will facilitate studies driving much needed biologic personalization of radiation therapy for improvements in patient outcomes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03603016
Volume :
110
Issue :
2
Database :
Academic Search Index
Journal :
International Journal of Radiation Oncology, Biology, Physics
Publication Type :
Academic Journal
Accession number :
150146410
Full Text :
https://doi.org/10.1016/j.ijrobp.2020.12.028