Back to Search
Start Over
Simple and Equipment-Free Paper-Based Device for Determination of Mercury in Contaminated Soil.
- Source :
-
Molecules . Apr2021, Vol. 26 Issue 7, p2004. 1p. - Publication Year :
- 2021
-
Abstract
- This work presents a simple and innovative protocol employing a microfluidic paper-based analytical device (µPAD) for equipment-free determination of mercury. In this method, mercury (II) forms an ionic-association complex of tetraiodomercurate (II) ion (HgI42−(aq)) using a known excess amount of iodide. The residual iodide flows by capillary action into a second region of the paper where it is converted to iodine by pre-deposited iodate to liberate I2(g) under acidic condition. Iodine vapor diffuses across the spacer region of the µPAD to form a purple colored of tri-iodide starch complex in a detection zone located in a separate layer of the µPAD. The digital image of the complex is analyzed using ImageJ software. The method has a linear calibration range of 50–350 mg L−1 Hg with the detection limit of 20 mg L−1. The method was successfully applied to the determination of mercury in contaminated soil and water samples which the results agreed well with the ICP-MS method. Three soil samples were highly contaminated with mercury above the acceptable WHO limits (0.05 mg kg−1). To the best of our knowledge, this is the first colorimetric µPAD method that is applicable for soil samples including mercury contaminated soils from gold mining areas. [ABSTRACT FROM AUTHOR]
- Subjects :
- *SOIL pollution
*CAPILLARY flow
*GOLD mining
*SOIL sampling
*SOIL moisture
*MERCURY
Subjects
Details
- Language :
- English
- ISSN :
- 14203049
- Volume :
- 26
- Issue :
- 7
- Database :
- Academic Search Index
- Journal :
- Molecules
- Publication Type :
- Academic Journal
- Accession number :
- 149715758
- Full Text :
- https://doi.org/10.3390/molecules26072004