Back to Search Start Over

High-resolution, non-contrast-enhanced magnetic resonance angiography of the wrist, hand and digital arteries using optimized implementation of Cartesian quiescent interval slice selective (QISS) at 1.5 T.

Authors :
Salehi Ravesh, Mona
Lebenatus, Annett
Bonietzki, Alexandra
Hensler, Johannes
Koktzoglou, Ioannis
Edelman, Robert R.
Graessner, Joachim
Jansen, Olav
Both, Marcus
Source :
Magnetic Resonance Imaging (0730725X). May2021, Vol. 78, p58-68. 11p.
Publication Year :
2021

Abstract

Non-contrast-enhanced (CE) magnetic resonance angiography (MRA) techniques are of considerable interest for diagnosing vascular diseases in the upper extremities owing to the possibility of repeated examinations, sufficient coverage of the measurement volume, and because possible side effects of administering iodine- or gadolinium-based contrast agents and radiation exposure can be avoided. The aim of this study was to investigate the feasibility of an optimized electrocardiogram (ECG) triggered Cartesian quiescent interval slice selective (QISS) technique for MRA of hand arteries. Both hands of 20 healthy volunteers (HVs) were examined using an optimized QISS-MRA pulse sequence at 1.5 Tesla. The wrist and hand arterial trees were divided into 36 segments. Cross-sectional areas (CSA) of all arterial segments were measured. For the technical evaluation of the pulse sequence, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed and six imaging artifacts were graded. Two experienced observers used an ordinal scoring system to assess the image quality of each arterial segment. Interobserver agreement was determined. The median CSA was 7.3 mm2 in the ulnar and radial artery, 3.2 mm2 in the four common digital arteries, and 1.5 mm2 in five proper digital arteries. The median SNR and CNR of the third common proper arteries were 45.9 and 20.3, respectively. None of the arterial segments were contaminated by venous enhancement. The image quality of arterial segments for both hands was considered as diagnostic in 87.2% of all 1440 segments. An interobserver agreement of 0.67 for both hands was determined for image quality of arterial segments using a five-grade scoring system. Optimized QISS-MRA allows as the first MRA technique the classification of superficial palmar arch (SPA) and deep palmar arch (DPA) variants. 5 new SPA and 6 new DPA variants could be classified using QISS-MRA in comparison with previous studies using CE computed tomography angiography and using fixed cadaver hands. By using this optimized 2D Cartesian QISS-MRA protocol, contrast agent-free angiography of the wrist and hand arteries provided a high in-plane spatial resolution and an excellent visualization of small digital arteries. • High-resolution, non CE MRA of the wrist, hand and digital arteries using optimized 2D ECG triggered Cartesian QISS at 1.5 T. • Optimized 2D ECG triggered Cartesian QISS-MRA allows complete suppression of venous signal intensity in digital arteries. • This pulse sequence allows for the first time the classification of superficial / deep palmar arch and (SPA/DPA) variants. • 5 new SPA and 6 new DPA variants could be classified in comparison with studies using CE CTA and using fixed cadaver hands. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0730725X
Volume :
78
Database :
Academic Search Index
Journal :
Magnetic Resonance Imaging (0730725X)
Publication Type :
Academic Journal
Accession number :
149294043
Full Text :
https://doi.org/10.1016/j.mri.2021.02.008