Back to Search Start Over

Enhanced selectivity and sensitivity for colorimetric determination of glyphosate using Mn–ZnS quantum dot embedded molecularly imprinted polymers combined with a 3D-microfluidic paper-based analytical device.

Authors :
Sawetwong, Pornchanok
Chairam, Sanoe
Jarujamrus, Purim
Amatatongchai, Maliwan
Source :
Talanta. Apr2021, Vol. 225, pN.PAG-N.PAG. 1p.
Publication Year :
2021

Abstract

We report a novel three-dimensional microfluidic paper-based analytical device (3D-μPAD) with colorimetric detection, using Mn–ZnS quantum dot embedded molecularly imprinted polymer (Mn–ZnS QD-MIP), for selective glyphosate determination in whole grain samples. Detection is based on the catalytic activity of Mn–ZnS QD-MIP in the H 2 O 2 oxidation of ABTS. Glyphosate imprinted polymer is successfully synthesized on the Mn–ZnS QD surface using a poly (N-isopropylacrylamide) (NIPAM) and N, N′-Methylenebisacrylamide (MBA) as the functional monomers. The catalytic activity depends on binding or non-binding of glyphosate molecules on the synthetic recognition sites of the Mn–ZnS QD-MIP. Glyphosate selectively binds to the cavities embedded on the Mn–ZnS QD surface, and subsequently turns-off or inhibits the ABTS oxidation and color change to light green. The change of reaction color from dark green to light green depends on the concentration of glyphosate. We report, for the first time, using the relatively new penguard enamel colour to create a hydrophobic barrier. The foldable 3D-μPAD comprises three layers (top/center/bottom), named as the detection zone, immobilized Mn–ZnS QD-MIP disc, and sample loading. Assay on the 3D-μPAD can determine glyphosate by ImageJ detection, over an operating range of 0.005–50 μg mL−1 and with a detection limit of 0.002 μg mL−1. Our 3D-μPAD exhibits high accuracy, with a 0.4% (intra-day) and 0.7% (inter-day) relative difference from the certified CRM value. Moreover, the fabricated 3D-μPAD provides good reproducibility (1.7% RSD for ten devices). The developed 3D-μPAD was successfully applied to determine the glyphosate concentration in whole grain samples and shows great promise as an alternative highly selective and sensitive colorimetric method. The 3D-μPAD is well suited to food-quality control and onsite environmental-monitoring applications, without sophisticated instrumentation. Image 1 • Mn–ZnS QD-MIP was synthesized for selective and sensitive glyphosate determination. • Colorimetric detection is based on glyphosate inhibit activity of Mn–ZnS QD-MIP in the H 2 O 2 oxidation of ABTS. • 3D-μPAD fabricated from Penguard enamel colour was firstly present. • The proposed 3D-μPAD exhibits high accuracy, sensitivity, selectivity and suitable for whole-grain samples. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00399140
Volume :
225
Database :
Academic Search Index
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
148633426
Full Text :
https://doi.org/10.1016/j.talanta.2020.122077