Back to Search Start Over

Inter‐individual variability in atrasentan exposure partly explains variability in kidney protection and fluid retention responses: A post hoc analysis of the SONAR trial.

Authors :
Koomen, Jeroen V.
Stevens, Jasper
Bakris, George
Correa‐Rotter, Ricardo
Hou, Fan Fan
Kitzman, Dalane W.
Kohan, Donald
Makino, Hirofumi
McMurray, John J. V.
Parving, Hans‐Henrik
Perkovic, Vlado
Tobe, Sheldon W.
Zeeuw, Dick
Heerspink, Hiddo J. L.
Source :
Diabetes, Obesity & Metabolism. Feb2021, Vol. 23 Issue 2, p561-568. 8p.
Publication Year :
2021

Abstract

Aim: To evaluate whether atrasentan plasma exposure explains between‐patient variability in urinary albumin‐to‐creatinine ratio (UACR) response, a surrogate for kidney protection, and B‐type natriuretic peptide (BNP) response, a surrogate for fluid expansion. Methods: Type 2 diabetic patients with chronic kidney disease (n = 4775) received 0.75 mg atrasentan for 6 weeks in the active run‐in period. Individual area under the concentration‐time‐curve (AUC) was estimated using a population pharmacokinetic model. The association between atrasentan AUC, other clinical characteristics, and UACR and BNP response, was estimated using linear regression. Results: The median atrasentan AUC was 43.8 ng.h/mL with a large variation among patients (2.5th‐97.5th percentiles [P]: 12.6 to 197.5 ng.h/mL). Median UACR change at the end of enrichment was −36.0% and median BNP change was 8.7%, which also varied among patients (UACR, 2.5th‐97.5th P: −76.2% to 44.5%; BNP, 2.5th‐97.5th P: −71.5% to 300.0%). In the multivariable analysis, higher atrasentan AUC was associated with greater UACR reduction (4.88% per doubling in ng.h/mL [95% confidence interval {CI}: 6.21% to 3.52%], P <.01) and greater BNP increase (3.08% per doubling in ng.h/mL [95% CI: 1.12% to 4.11%], P <.01) independent of estimated glomerular filtration rate, haemoglobin or BNP. Caucasian patients compared with black patients had greater UACR reduction (7.06% [95% CI: 1.38% to 13.07%]) and also greater BNP increase (8.75% [95% CI: 1.65% to 15.35%]). UACR response was not associated with BNP response (r = 0.06). Conclusion: Atrasentan plasma exposure varied among individual patients and partially explained between‐patient variability in efficacy and safety response. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14628902
Volume :
23
Issue :
2
Database :
Academic Search Index
Journal :
Diabetes, Obesity & Metabolism
Publication Type :
Academic Journal
Accession number :
148069160
Full Text :
https://doi.org/10.1111/dom.14252