Back to Search
Start Over
Direct Analysis of Glyphosate, Glufosinate, and Their Metabolites in Palm Oil Using Liquid Chromatography with Tandem Mass Spectrometry.
- Source :
-
Journal of AOAC International . Nov/Dec2020, Vol. 103 Issue 6, p1528-1533. 6p. - Publication Year :
- 2020
-
Abstract
- Background: Glyphosate and glufosinate are broad-spectrumherbicides which are frequently used in palm oil plantations for weed control. Metabolites of these herbicides are known to have environmental and food safety implications. As there is no validated method for multiresidue testing of these herbicides and their metabolites in palm oil products, a new method was needed for the purpose of regulatory analysis. Objective: In this study, we endeavored to develop a rapid method for multi residue analysis of glyphosate (+aminomethylphosphonic acid) and glufosinate (+3-methylphosphinicopropionic acid and N-acetyl-glufosinate) in refined and crude palm oil matrices using liquid chromatography (LC) tandem mass spectrometry (MS/MS). Method: The optimized sample preparation workflow included extraction of refined or crude palm oil (10 g) with acidified water (0.1M HCl), cleanup by phase separation with dichloromethane, and analysis by LC-MS/MS with multiple reaction monitoring. Results: The use of a Torus-DEA LC column ensured simultaneous analysis of these compounds within a runtime of 10min. The LOQ of these analytes was 0.01mg/kg, except that of aminomethylphosphonic acid which was 0.02mg/kg. The method sensitivity complied with the national maximum residue limits of Malaysia and the European Union. Also, the method selectivity, sensitivity, accuracy, and precision were aligned with the SANTE/12682/2019 guidelines of analytical quality control. Conclusions: The potentiality of the optimized method lies in a high throughput direct analysis of glyphosate and glufosinate with their metabolites in a single chromatographic run. The method is fit for purpose for regulatory testing of these residues in a broad range of palm oil matrices. Highlights: The study reports for the first time a validated method for simultaneous analysis of glyphosate, glufosinate, and their metabolites in a range of palm oil products. The method did not require a derivatization step and provided a high throughput analysis of these compounds with satisfactory selectivity, sensitivity, accuracy, and precision. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10603271
- Volume :
- 103
- Issue :
- 6
- Database :
- Academic Search Index
- Journal :
- Journal of AOAC International
- Publication Type :
- Academic Journal
- Accession number :
- 147632347
- Full Text :
- https://doi.org/10.1093/jaoacint/qsaa066