The Effects of Cable Capacitance on Longwall Power Systems.

Authors :
Novak, Thomas
Basar, Joseph
Sottile, Joseph
Kohier, Jeffery L.
Source :
IEEE Transactions on Industry Applications. Sep/Oct2004, Vol. 40 Issue 5, p1406-1412. 7p.
Publication Year :
2004

Abstract

Utilization voltages used on longwall equipment operating in coal mines in the United States have increased steadily over the past 15 years from 1000 up to 4160 V. This voltage in- crease has directly influenced the 200% gain in overall longwall productivity from 1987 to the present. The transition from medium voltage (661-1000 V) to high voltage (greater than 1000 V) has permitted significant increases in mining face widths and equipment sizes. Longwall systems with total connected loads of over 5000 hp are now common, and all longwalls in the United States now use high-voltage equipment, with the majority utilizing 4160 V. Shielded cables, which have significantly more capacitance than unshielded cables, are required for high-voltage applications in the mining industry. This capacitance can have detrimental influences on system overvoltages and relay selectivity during ground-fault conditions if the values for the neutral grounding resistor and the ground-fault-relay pickup settings are improperly chosen. These issues are addressed in this paper. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00939994
Volume :
40
Issue :
5
Database :
Academic Search Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
14674366
Full Text :
https://doi.org/10.1109/TIA.2004.834025