Back to Search
Start Over
Design and fabrication of a smart sensor using in silico epitope mapping and electro-responsive imprinted polymer nanoparticles for determination of insulin levels in human plasma.
- Source :
-
Biosensors & Bioelectronics . Dec2020, Vol. 169, pN.PAG-N.PAG. 1p. - Publication Year :
- 2020
-
Abstract
- A robust and highly specific sensor based on electroactive molecularly imprinted polymer nanoparticles (nanoMIP) was developed. The nanoMIP tagged with a redox probe, combines both recognition and reporting capabilities. The developed nanoMIP replaces enzyme-mediator pairs used in traditional biosensors thus, offering enhanced molecular recognition for insulin, improving performance in complex biological samples, and yielding high stability. Also, most of existing sensors show poor performance after storage. To improve costs of the logistics and avoid the need of cold storage in the chain supply, we developed an alternative to biorecognition system that relies on nanoMIP. NanoMIP were computationally designed using "in-silico" insulin epitope mapping and synthesized by solid phase polymerisation. The characterisation of the polymer nanoparticles was performed by transmission electron microscopy (TEM), dynamic light scattering (DLS), Fourier-transform Infrared (FT-IR) and surface plasmon resonance (SPR). The electrochemical sensor was developed by chemical immobilisation of the nanoMIP on screen printed platinum electrodes. The insulin sensor displayed satisfactory performances and reproducible results (RSD = 4.2%; n = 30) using differential pulse voltammetry (DPV) in the clinically relevant concentration range from 50 to 2000 pM. The developed nanoMIP offers the advantage of large number of specific recognition sites with tailored geometry, as the resultant, the sensor showed high sensitivity and selectivity to insulin with a limit of detection (LOD) of 26 and 81 fM in buffer and human plasma, respectively, confirming the practical application for point of care monitoring. Moreover, the nanoMIP showed adequate storage stability of 168 days, demonstrating the robustness of sensor for several rounds of insulin analysis. • The molecularly imprinted polymer nanoparticles tagged with a redox probe, combines both recognition and reporting functions. • The electroactive nanoparticles system replaces enzyme-mediator pairs used in classic biosensors. • Nanoparticles were computationally designed to selectively bind insulin epitopes. • The sensor devised provides adequate selectivity, low cross-reactivity and high sensitivity in plasma. • This technology is robust and can be potentially applied to a broad range of targets. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 09565663
- Volume :
- 169
- Database :
- Academic Search Index
- Journal :
- Biosensors & Bioelectronics
- Publication Type :
- Academic Journal
- Accession number :
- 146361406
- Full Text :
- https://doi.org/10.1016/j.bios.2020.112536