Back to Search Start Over

Comparison of two biomarker only algorithms for early risk stratification in patients with suspected acute coronary syndrome.

Authors :
Kavsak, Peter A.
Mondoux, Shawn E.
Ma, Jinhui
Sherbino, Jonathan
Hill, Stephen A.
Clayton, Natasha
Mehta, Shamir R.
Griffith, Lauren E.
McQueen, Matthew
Devereaux, P.J.
Worster, Andrew
Source :
International Journal of Cardiology. Nov2020, Vol. 319, p140-143. 4p.
Publication Year :
2020

Abstract

We developed a biomarker algorithm encompassing the clinical chemistry score (CCS; which includes the combination of a random glucose concentration, an estimated glomerular filtration rate and high-sensitivity cardiac troponin; hs-cTn) with the Ortho Clinical Diagnostics hs-cTnI assay (CCS-serial) and compared it to the cutoffs derived from Ortho Clinical Diagnostics 0/1 h (h) algorithm for 7-day myocardial infarction (MI) or cardiovascular (CV)-death. The study cohort was an emergency department (ED) population (n = 906) with symptoms suggestive of acute coronary syndrome (ACS) who had two Ortho hs-cTnI results approximately 3 h apart. Diagnostic parameters (sensitivity/specificity/negative predictive value; NPV/positive predictive value; PPV) were derived for the CCS-serial and the 0/1 h algorithm for 7-day MI/CV-death. A safety analysis was performed for patients in the rule-out arms of the algorithms for 30-day MI/death. The CCS-serial algorithm yielded 100% sensitivity/NPV (32% low-risk) and 95.7% specificity/65% PPV (11% high-risk). The 0/1 h algorithm-cutoffs yielded sensitivity/NPV/specificity/PPV of 97.8%/99.4%/91.3%/50%, which classified 38% of patients as low-risk and 16% of patients as high-risk. Four patients (1.2%) in the 0/1 h algorithm-cutoff rule-out arm had a 30-day MI/death outcome as compared to zero patients in the CCS-serial rule-out arm (p = 0.06). Both the CCS-serial and 0/1 h algorithm cutoffs yield high NPVs with a similar proportion of patients identified as low-risk. These data may be useful for sites who are unable to collect samples at 0/1 h in the emergency department. • Biomarker only algorithms used in patients with possible ACS. • 0/1 h algorithm and clinical chemistry score algorithm provide high NPV. • Both algorithms can be used at 0 and 3 h sampling timeframes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01675273
Volume :
319
Database :
Academic Search Index
Journal :
International Journal of Cardiology
Publication Type :
Academic Journal
Accession number :
146192508
Full Text :
https://doi.org/10.1016/j.ijcard.2020.06.066