Back to Search Start Over

A framework for the analysis of polar anticancer drugs in wastewater: On-line extraction coupled to HILIC or reverse phase LC-MS/MS.

Authors :
Vaudreuil, Marc-Antoine
Vo Duy, Sung
Munoz, Gabriel
Furtos, Alexandra
Sauvé, Sébastien
Source :
Talanta. Dec2020, Vol. 220, pN.PAG-N.PAG. 1p.
Publication Year :
2020

Abstract

With the consumption of chemotherapy agents, residues of anticancer drugs may be increasingly found in hospital and municipal wastewaters. Quantification of these highly polar micropollutants remains challenging due to poor chromatographic retention on typical reversed phases. This study investigated different solid-phase extraction (SPE) materials for automated on-line preconcentration of complex matrices (hospital and municipal wastewaters) and various chromatographic column options. A hyper crosslinked hydroxylated polystyrene-divinylbenzene copolymer SPE sorbent coupled on-line with hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC-MS/MS) yielded suitable limits of detection (LOD: 1–2 ng L−1) for 5-fluorouracil (5-FU) and 2',2'-difluorodeoxyuridine (dFdU). Optimization of chromatographic conditions led to a single LC-MS/MS method for the analysis of other cytostatic drugs including cytarabine (CYT), gemcitabine (GEM), methotrexate (MTX), ifosfamide (IFO), cyclophosphamide (CYC) and capecitabine (CAP). The filter membrane for sample pre-treatment, HPLC mobile phase additives, and on-line SPE loading parameters were also investigated. The methods were validated in wastewater matrix with suitable determination coefficients (R2 range: 0.9982–0.9999), LODs (0.5–5 ng L−1), accuracy (78–111%), intraday precision (2.6–12%), and interday precision (2.1–13%). The occurrence of cytostatic drugs was examined in field-collected water samples from hospital effluents and municipal wastewater treatment plants (WWTP) in Canada. CAP (3.7–64 ng L−1), dFdU (6.1–300 ng L−1), and MTX (1.8–68 ng L−1) were frequently detected across both matrix types, while IFO was detected in hospital wastewater (23–140 ng L−1) but not in municipal WWTPs. Image 1 • On-line SPE was successfully coupled with HILIC-MS/MS to analyze water samples. • First on-line workflow for ultra-trace detection of the polar anticancer drug 5-FU. • Combinations of 5 SPE x 12 analytical columns were screened for 8 anticancer drugs. • Two HILIC & RPLC-MS/MS methods presented suitable LODs (0.5–5 ng L−1) in wastewater. • dFdU, CYT, GEM, MTX, IFO, CYC & CAP were detected in hospital & urban wastewaters. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00399140
Volume :
220
Database :
Academic Search Index
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
145699336
Full Text :
https://doi.org/10.1016/j.talanta.2020.121407