Back to Search Start Over

Electronic synergy between ligands of luminol and isophthalic acid for fluorescence ratiometric detection of Hg2+.

Authors :
Tong, Yuan-Jun
Qi, Jia-Xin
Song, An-Min
Zhong, Xiao-Li
Jiang, Wei
Zhang, Li
Liang, Ru-Ping
Qiu, Jian-Ding
Source :
Analytica Chimica Acta. Sep2020, Vol. 1128, p11-18. 8p.
Publication Year :
2020

Abstract

Stimulus-responsive double-ligand luminol-Eu-IPA infinite coordination polymer nanoparticles (luminol-Eu-IPA CPNPs) were prepared as a ratiometric fluorescence probe for highly selective detecting Hg2+. The CPNPs were constituted of Eu3+ as the nuclear metal coordinated by isophthalic acid (IPA) together with luminol as an auxiliary ligand. The photoinduced electron transfer (PET) occurring from IPA to luminol prevented the antenna effect between IPA and Eu3+, leading to the quench fluorescence of Eu3+ under light excitation. As Hg2+ has a high affinity to N atom of luminol and the spin-orbit coupling effect, spectroscopically and magnetically silent properties, the fluorescence intensity of luminol was quenched. Meanwhile, the PET effect between luminol and IPA was interrupted under the presence of Hg2+. This process resulted in a significant decrease in the fluorescence intensity of luminol and a significant increase in the fluorescence intensity of Eu3+. Therefore, the fluorescence ratiometric detection of Hg2+ was performed by monitoring the ratio of the fluorescence at 617 nm of Eu3+ to that at 430 nm of luminol. The linear range was from 0.05 to 20 μM with a detection limit as low as 13.2 nM Hg2+ (S/N = 3). Due to the fluorescence of luminol be quenched and the effect of PET be disrupted simultaneously, the probe exhibiting excellent detection selectively can avoid false positive signals, which was demonstrated for monitoring mercury ions in real water samples. Precision in positioning ligands in CPNPs is an advantage to achieve high specificity in comparison to traditional organic dendrimers or precious metal nanomaterials. Image 1 • An effective lanthanide ratiometric fluorescent probe for Hg2+ based on luminol-Eu-IPA CPNPs has been demonstrated. • The photoinduced electron transfer occurring from luminol to IPA prevents the antenna effect between IPA and Eu3+. • The fluorescence of luminol is quenched and the effect of PET is disrupted simultaneously under the presence of Hg2+. • The ratiometric probe exhibiting excellent detection selectively can avoid false positive signals. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00032670
Volume :
1128
Database :
Academic Search Index
Journal :
Analytica Chimica Acta
Publication Type :
Academic Journal
Accession number :
145203965
Full Text :
https://doi.org/10.1016/j.aca.2020.06.047