Back to Search
Start Over
Towards multi-center glaucoma OCT image screening with semi-supervised joint structure and function multi-task learning.
- Source :
-
Medical Image Analysis . Jul2020, Vol. 63, pN.PAG-N.PAG. 1p. - Publication Year :
- 2020
-
Abstract
- • It is the first study on unifying structure analysis and function regression for glaucoma screening from OCT images. • The semi-supervised smoothness assumption is made to solve the missing regression label problem. • A multi-task learning network is proposed to explore the structure-function relationship for glaucoma screening. • Extensive experiments on large-scale multi-center datasets demonstrate the effectiveness of the multi-task learning model. Glaucoma is the leading cause of irreversible blindness in the world. Structure and function assessments play an important role in diagnosing glaucoma. Nowadays, Optical Coherence Tomography (OCT) imaging gains increasing popularity in measuring the structural change of eyes. However, few automated methods have been developed based on OCT images to screen glaucoma. In this paper, we are the first to unify the structure analysis and function regression to distinguish glaucoma patients from normal controls effectively. Specifically, our method works in two steps: a semi-supervised learning strategy with smoothness assumption is first applied for the surrogate assignment of missing function regression labels. Subsequently, the proposed multi-task learning network is capable of exploring the structure and function relationship between the OCT image and visual field measurement simultaneously, which contributes to classification performance improvement. It is also worth noting that the proposed method is assessed by two large-scale multi-center datasets. In other words, we first build the largest glaucoma OCT image dataset (i.e., HK dataset) involving 975,400 B-scans from 4,877 volumes to develop and evaluate the proposed method, then the model without further fine-tuning is directly applied on another independent dataset (i.e., Stanford dataset) containing 246,200 B-scans from 1,231 volumes. Extensive experiments are conducted to assess the contribution of each component within our framework. The proposed method outperforms the baseline methods and two glaucoma experts by a large margin, achieving volume-level Area Under ROC Curve (AUC) of 0.977 on HK dataset and 0.933 on Stanford dataset, respectively. The experimental results indicate the great potential of the proposed approach for the automated diagnosis system. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 13618415
- Volume :
- 63
- Database :
- Academic Search Index
- Journal :
- Medical Image Analysis
- Publication Type :
- Academic Journal
- Accession number :
- 143557406
- Full Text :
- https://doi.org/10.1016/j.media.2020.101695