Back to Search Start Over

Local active isolation of the AEI-SAS for the AEI 10 m prototype facility.

Authors :
Kirchhoff, R
Mow-Lowry, C M
Bergmann, G
Hanke, M M
Koch, P
Köhlenbeck, S M
Leavey, S
Lehmann, J
Oppermann, P
Wöhler, J
Wu, D S
Lück, H
Strain, K A
Source :
Classical & Quantum Gravity. 6/4/2020, Vol. 37 Issue 11, p1-22. 22p.
Publication Year :
2020

Abstract

High precision measurements in various applications rely on active seismic isolation to decouple the experiment from seismic motion; therefore, closed feed-back control techniques such as sensor blending and sensor correction are commonly implemented. This paper reviews the active isolation techniques of the Albert Einstein Institute seismic attenuation system (AEI-SAS). Two approaches to improve the well known techniques are presented. First, the influence of the sensor basis for the signal-to-noise ratio in the chosen coordinate system is calculated and second, a procedural optimization of blending filters to minimize the optical table velocity is performed. Active isolation techniques are adapted to the mechanical properties and the available sensors and actuators of the AEI-SAS. The performance of the final isolation is presented and limitations to the isolation are analyzed in comparison to a noise model. The optical table motion reaches approximately at 1 Hz, reducing the ground motion by a factor of approximately 100. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02649381
Volume :
37
Issue :
11
Database :
Academic Search Index
Journal :
Classical & Quantum Gravity
Publication Type :
Academic Journal
Accession number :
143366081
Full Text :
https://doi.org/10.1088/1361-6382/ab857e