Voltammetric analysis for distinguishing portal hypertension-related from malignancy-related ascites: A proof of concept study.
- Source :
-
PLoS ONE . 5/21/2020, p1-12. 12p. - Publication Year :
- 2020
-
Abstract
- Background: Serum-ascites albumin gradient (SAAG) remains the most sensitive and specific marker for the differentiation of ascites due to portal hypertension from ascites due to other causes. SAAG has some limitations and may fail in selected conditions. Voltammetric analysis (VA) has been used for the detection of electroactive species of biological significance and has proven effective for detection infections in biological fluids. Aims: In this study, we compared the accuracy of voltammetric analysis (VA) with that of SAAG to differentiate ascites due to portal hypertension from that having a different origin. Methods: 80 ascites samples were obtained from patients undergoing paracentesis at the Campus Bio-Medico Hospital of Rome. VA was performed using the BIONOTE device. The ability of VA to discriminate ascitic fluid etiology and biochemical parameters was evaluated using Partial Least Square Discriminant Analysis (PLS-DA), with ten-fold cross-validations. Results: Mean age was 68.6 years (SD 12.5), 58% were male. Ascites was secondary to only portal hypertension in 72.5% of cases (58 subjects) and it was secondary to a baseline neoplastic disease in 27.5% of cases (22 subjects). Compared to SAAGâ„1.1, e-tongue predicted ascites from portal hypertension with a better accuracy (92.5% Vs 87.5%); sensitivity (98.3% Vs 94.8%); specificity (77.3% Vs 68.2%); predictive values (PPV 91.9% Vs 88.7% and NPV 94.4% Vs 83.3%). VA correctly classified ascites etiology in 57/58 (98.2%) of cases with portal hypertension and in 17/22 (77.2%) of cases with malignancy. Instead, VA showed poor predictive capacities towards total white blood count and polymorphonuclear cell count. Conclusions: According to this proof of concept study, VA qualifies as a promising low-cost and easy method to discriminate between ascites secondary to portal hypertension and ascites due to malignancy. [ABSTRACT FROM AUTHOR]
- Subjects :
- *LEUKOCYTE count
*ASCITES
*PROOF of concept
*PORTAL hypertension
*ASCITIC fluids
Subjects
Details
- Language :
- English
- ISSN :
- 19326203
- Database :
- Academic Search Index
- Journal :
- PLoS ONE
- Publication Type :
- Academic Journal
- Accession number :
- 143361770
- Full Text :
- https://doi.org/10.1371/journal.pone.0233350