Abstract

This article presents and analyzes a wide-locking range divide-by-5 injection-locked frequency divider (ILFD) manufactured in the TSMC 0.18- $\mu \text{m}$ processes. The ILFD uses the balanced injection method and uses the pure harmonic mixing approach at low injection power, and it is designed with an RLC dual-resonance resonator. The harmonic mixer relies on the self-generated second harmonic, which increases with injection power. Because of no narrowband filter as used in the linear mixer counterpart, the divide-by-5 ILFD uses a wideband design method. In addition, the ILFD enhances the divide-by-5 locking range via the overlapped dual-band locking ranges as verified by both experiment and simulation. At the drain–source bias ${V} _{\text{DD}}$ of 0.8 V and at the incident power of 0 dBm, the locking range of the divide-by-5 ILFD is 3.6 GHz, from the incident frequency 13.0–16.6 GHz with the percentage 24.3%. The core power consumption is 4.09 mW, and the die area is $1.02\times0.93$ mm2. [ABSTRACT FROM AUTHOR]