Two-phase refrigerant flow in the evaporator of a stirling cooling system with a thermosyphon loop.

Authors :
Celik, Serdar
Ekren, Orhan
Source :
Experimental Heat Transfer. 2020, Vol. 33 Issue 4, p305-317. 13p. 2 Diagrams, 3 Charts, 7 Graphs.
Publication Year :
2020

Abstract

In this study, implementation of a thermosyphon heat exchanger into a Stirling refrigeration system is demonstrated by means of both theoretical and experimental analyses. R-134a was employed as the working fluid which formed a liquid column at the condenser exit, enabling a two-phase flow through the evaporator. Experiments were conducted in a controlled chamber. Cooling capacity, coefficient of performance, and two-phase pressure drop of the cooler were compared at two different voltages. The flow regime for the refrigerant in the evaporator was found to be stratified based on the calculated wavy flow and Lockhart–Martinelli parameters. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08916152
Volume :
33
Issue :
4
Database :
Academic Search Index
Journal :
Experimental Heat Transfer
Publication Type :
Academic Journal
Accession number :
143251476
Full Text :