Back to Search
Start Over
Evaluation of polymerization shrinkage of bulk-fill resin composites using microcomputed tomography.
- Source :
-
Clinical Oral Investigations . May2020, Vol. 24 Issue 5, p1687-1693. 7p. 2 Color Photographs, 2 Charts. - Publication Year :
- 2020
-
Abstract
- Objectives: This study evaluated the influence of cavity depth on polymerization shrinkage of bulk-fill resin composites with and without adhesive resin. Materials and methods: Standardized box-shaped cavities (width, 4 mm; length, 5 mm, depth, 2 mm or 4 mm) were made on occlusal surfaces of extracted human third molars (N = 60). The teeth were assigned to 3 groups to receive bulk-fill resin composites (low-viscosity bulk-fill, SDR; high-viscosity bulk-fill; Filtek Bulk-Fill—FB; and TetricEvo Ceram Bulk-Fill—TB) in the prepared cavities with and without adhesive resin (Clearfil S3 Bond). Each specimen (n = 5 per group) was scanned twice using microcomputed tomography (micro-CT): once after application of the resin composite to the cavity prior to polymerisation and once after polymerisation. The shrinkage of volumetric loss (%) was measured using micro-CT. Data were analysed using Kruskal-Wallis and Mann-Whitney U tests (alpha = 0.05). Results: The material type (p < 0.05), application of adhesive resin (p < 0.05) and cavity depth (p < 0.05) significantly affected the shrinkage values. The interaction terms were also significant (p < 0.05). All the bulk-fill resin composites tested showed significantly less shrinkage when applied in cavities with adhesive resin (0.94–2.55) compared with those without (2.01–3.45) (p < 0.05) and presented significantly more shrinkage after polymerisation (p < 0.05). At a 2-mm cavity depth without (2 mm, 2.28; 4 mm, 2.41) and with adhesive (2 mm, 0.94; 4 mm, 1.67), significantly less shrinkage was observed with FB compared with SDR and TB (p < 0.05). At a 4-mm cavity depth without (3.14) and with adhesive (2.55), SDR showed significantly higher shrinkage compared with FB and TB (p < 0.05). Conclusions: The bulk-fill composites tested presented less shrinkage when used in conjunction with adhesive resin application on dentin. Overall, the low-viscosity bulk-fill resin SDR showed more shrinkage compared with high-viscosity resins tested. Clinical relevance: Low- or high-viscosity bulk-fill resin composites should be applied on dentin after application of adhesive resin to decrease shrinkage. [ABSTRACT FROM AUTHOR]
- Subjects :
- *MANN Whitney U Test
*THIRD molars
*RESIN adhesives
*TOMOGRAPHY
*POLYMERIZATION
Subjects
Details
- Language :
- English
- ISSN :
- 14326981
- Volume :
- 24
- Issue :
- 5
- Database :
- Academic Search Index
- Journal :
- Clinical Oral Investigations
- Publication Type :
- Academic Journal
- Accession number :
- 143000229
- Full Text :
- https://doi.org/10.1007/s00784-019-03025-5