Back to Search Start Over

Multi-objective optimization and exergoeconomic analysis of a continuous solar-driven system with PCM for power, cooling and freshwater production.

Authors :
Abbasi, Hamid Reza
Pourrahmani, Hossein
Source :
Energy Conversion & Management. May2020, Vol. 211, pN.PAG-N.PAG. 1p.
Publication Year :
2020

Abstract

• An integrated system is proposed to produce power, cooling, and freshwater. • Novel Thermal Energy Storage (TES) is suggested using phase change material (PCM). • Using high temperature PCM for TES, continuous operation of system is feasible. • The overall energy and exergy efficiencies are 40.52% and 14.40%, respectively. • The LCoE of the plant follows the downward trend of concentrated solar plants. In this article, three different modes of a novel integrated system would be evaluated by the application of high temperature Thermal Energy Storage (TES) to produce electricity, cooling, and freshwater. Freshwater is produced using the reverse osmosis (RO) desalination unit while Absorption Refrigeration Cycle (ARC) provides cooling. In this system, a high temperature Phase Change Material (PCM) is utilized to make the system working continuously even at nights. The output heat of gas turbine (GT) is also recovered utilizing the Organic Rankine Cycle (ORC). According to exergoeconomic analysis, the efficiencies, exergy destructions and product cost rates are computed. The multi-objective optimization has also been performed considering six different ORC working fluids and the changes in the direct normal irradiation of a city in Iran. In the trigeneration condition, the optimum values of the GT's compressor pressure ratio and ORC's turbine inlet pressure were obtained 9.06 and 3300 kPa, respectively. The exergy efficiency of the suggested system at the optimal condition is computed to be 14.40%, while that of energy is 40.52% with the total product cost rate of 30.524 $/GJ. The produced cooling capacity of the absorption system is also 1.62 MW whereas the output amount of freshwater and electricity for the users are about 5209.5 m3/day and 2.42 MW, respectively. The Levelized Cost of Electricity (LCoE) is also calculated to be 0.2341 $/kWh, which shows promising economic performance. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01968904
Volume :
211
Database :
Academic Search Index
Journal :
Energy Conversion & Management
Publication Type :
Academic Journal
Accession number :
142950269
Full Text :
https://doi.org/10.1016/j.enconman.2020.112761