Back to Search
Start Over
Dynamic response-based LEDs health and temperature monitoring.
- Source :
-
Measurement (02632241) . May2020, Vol. 156, pN.PAG-N.PAG. 1p. - Publication Year :
- 2020
-
Abstract
- • We demonstrated new indicators of GaN LED temperature. • We have found highly sensitive GaN LED temperature predictors. • We demonstrated new indicator of LED health and imminent failures. This paper presents a number of novel methods to measure the junction temperature and to estimate the health of gallium nitride light-emitting diodes (LEDs). The methods are based on measurements of the dynamic impedance and optical output. Our experimental analysis reveals temperature sensitive parameters of the electrical and optical responses. Moreover, a correlation between the non-radiative current characterizing the active region defects and the small-signal impedance is shown. The demonstrated methods can be applied to enhance existing temperature-monitoring techniques. The derived dependencies also build a foundation for advanced in-field health monitoring of the LEDs using the infrastructure of visible light communication systems. Such methods and techniques are valuable for predictive maintenance of solid state lighting systems. [ABSTRACT FROM AUTHOR]
- Subjects :
- *OPTICAL communications
*TELECOMMUNICATION systems
*VISIBLE spectra
*TEMPERATURE
Subjects
Details
- Language :
- English
- ISSN :
- 02632241
- Volume :
- 156
- Database :
- Academic Search Index
- Journal :
- Measurement (02632241)
- Publication Type :
- Academic Journal
- Accession number :
- 142206210
- Full Text :
- https://doi.org/10.1016/j.measurement.2020.107599