Back to Search Start Over

In situ, portable and robust laser sensor for simultaneous measurement of ammonia, water vapor and temperature in denitrification processes of coal fired power plants.

Authors :
Li, Jinyi
Zhang, Chenge
Wei, Yingying
Du, Zhenhui
Sun, Fushuang
Ji, Yue
Yang, Xiaotao
Liu, Chang
Source :
Sensors & Actuators B: Chemical. Feb2020, Vol. 305, pN.PAG-N.PAG. 1p.
Publication Year :
2020

Abstract

• An in-situ, portable and robust laser sensor system was developed for measurement of NH 3 , H 2 O and T in the deNOx process. • A calibration-free WMS-VMA was proposed to ensure the high-performance of the tri-spectral line analysis. • An algorithm was presented for simultaneous, rapid and accurate inversion of multiple parameters. • The sensor system has great potential of ammonia injection optimization in deNOx process of CFPPs. Simultaneous measurement of the ammonia, flue gas temperature and water vapor concentration in denitrification (deNOx) processes is of great importance for improving the deNOx efficiency of coal-fired power plants (CFPPs) and maximizing energy conservation and emission reduction. A portable, robust, low-cost and low-power laser sensor was developed based on wavelength modulation spectroscopy (WMS) with a single near infrared diode laser, which covers the optimized NH 3 spectral line at 6612.73 cm−1 and H 2 O line pair at 6612.02 and 6609.85 cm−1. A calibration-free for WMS with varied modulation amplitude (WMS-VMA) was proposed to improve the performance of the tri-spectral line analysis. A probe, based on Herriott cell structure, coupled with deformation resistance, dust-proof, air-tight and anti-seismic, was design to adapt to the harsh environment of CFPPs. Lab-based sensor evaluation showed that the measurement accuracies for the temperature, H 2 O and NH 3 concentration are 2.9 %, 4.8 % and 5.1 %, respectively. Allan variance analysis shows that the sensor has good stability, and the measurement sensitivity at five-second resolution are 0.1 ppm and 0.03 % for NH 3 and H 2 O concentration, respectively. Furthermore, the feasibility of the sensor system was also verified by field tests at both deNOx inlet and outlet in a practical CFPP, denoting great potential of ammonia injection optimization in deNOx process. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09254005
Volume :
305
Database :
Academic Search Index
Journal :
Sensors & Actuators B: Chemical
Publication Type :
Academic Journal
Accession number :
141109963