Back to Search
Start Over
Effect of change in position of particle dampers on wind turbine blade for vibration suppression.
- Source :
-
Vibroengineering Procedia . Nov2019, Vol. 29, p37-42. 6p. - Publication Year :
- 2019
-
Abstract
- Wind turbine energy minimizes due to vibration of blade. In this research we focus on vibration suppression by using particle damping technique. Containers are used for fill the particles and mounted on the blade. As vibration of blade increases, it increases the movement of containers along with particles this brings particle to particle and particle to container wall collision takes place which results to energy loss. In this study we use four different positions for mounting containers, firstly on all four different positions we mount containers simultaneously and take three readings for three different ball sizes respectively, keeping 50% fill constant in all readings. Then we reduce one container among four and take the readings. Repeat this procedure up to single container. Compare with damping results with without damping results and finding out optimum locations for mounting of dampers. [ABSTRACT FROM AUTHOR]
- Subjects :
- *WIND turbine blades
*PARTICLES
*ENERGY dissipation
*WIND power
*WIND turbines
Subjects
Details
- Language :
- English
- ISSN :
- 23450533
- Volume :
- 29
- Database :
- Academic Search Index
- Journal :
- Vibroengineering Procedia
- Publication Type :
- Academic Journal
- Accession number :
- 139917572
- Full Text :
- https://doi.org/10.21595/vp.2019.20921