Back to Search Start Over

A Nonrotating Multiparameter 3-D X-Ray Imaging System Part II: Design and ExperimentsL.

Authors :
Jama, Hassan A.
Hussein, Esam M. A.
Khettabi, Faysal El
Source :
IEEE Transactions on Nuclear Science. Jun2004 Part 2 of 4, Vol. 51 Issue 3, p648-658. 11p.
Publication Year :
2004

Abstract

The design aspects of a 3-D X-ray imaging system that eliminates the rotation process associated with tomographic systems are discussed. The processes of selecting the proper X-ray voltage and the beam configuration are addressed. A rectilinear scanning mechanism is introduced. The choice and design of detector assemblies are described. The paper presents the results of experiments devised to progressively test the performance and response of the system. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189499
Volume :
51
Issue :
3
Database :
Academic Search Index
Journal :
IEEE Transactions on Nuclear Science
Publication Type :
Academic Journal
Accession number :
13914060
Full Text :
https://doi.org/10.1109/TNS.2004.829602