Back to Search Start Over

Comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA: can one tracer replace the other?

Authors :
Andersen, Trine B.
Jødal, Lars
Nielsen, Nikolaj S.
Petersen, Lars J.
Source :
Scandinavian Journal of Clinical & Laboratory Investigation. Nov2019, Vol. 79 Issue 7, p463-467. 5p.
Publication Year :
2019

Abstract

Both 99mTc-DTPA and 51Cr-EDTA are widely used to determine glomerular filtration rate (GFR), but few direct comparative studies exist. The shortage of 51Cr-EDTA makes a direct comparison highly relevant. The aim of the study was to investigate if there is any clinically relevant difference between plasma clearance of 99mTc-DTPA and 51Cr-EDTA. Patients ≥18 years of age referred for routine GFR measurement by 51Cr-EDTA were prospectively enrolled. The two tracers (10 MBq 99mTc-DTPA (CaNa3-DTPA) and 2.5 MBq 51Cr-EDTA) were intravenously injected at time zero. A standard 4-sample technique was applied with samples collected at 180, 200, 220 and 240 min, if the estimated GFR (eGFR) was ≥30 mL/min. A comparison of single-sample GFR based on the 200 min sample was also conducted. Fifty-six patients were enrolled in the study. All patients had an estimated GFR >30 mL/min/1.73 m2. No patients suffered from ascites or significant oedema. The mean 51Cr-EDTA plasma clearance was 82 mL/min (range 16-226). The plasma clearances determined by the two methods were highly correlated (r = 0.993). The plasma clearance was significantly higher when measured by 99mTc-DTPA than by 51Cr-EDTA (p = 0.01), but the numerical difference was minimal (mean difference 1.4 mL/min; 95% limits of agreement (LOA) -6.6 to 9.4). The difference between the two methods was independent of the level of renal function. Similar results were found for one-sample GFR. No clinically relevant differences were found between the plasma clearance of 99mTc-DTPA and that of 51Cr-EDTA. Therefore, 99mTc-DTPA can replace 51Cr-EDTA when needed. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00365513
Volume :
79
Issue :
7
Database :
Academic Search Index
Journal :
Scandinavian Journal of Clinical & Laboratory Investigation
Publication Type :
Academic Journal
Accession number :
139081825
Full Text :
https://doi.org/10.1080/00365513.2019.1658217