High heat flux test results for a thermal break DEMO divertor target and subsequent design and manufacture development.

Authors :
Lukenskas, Adomas
Barrett, T.R.
Fursdon, M.
Domptail, F.
Schoofs, F.
Greuner, H.
Dose, G.
Roccella, S.
Visca, E.
Gallay, F.
Richou, M.
You, J.-H.
Source :
Fusion Engineering & Design. Sep2019:Part B, Vol. 146, p1657-1660. 4p.
Publication Year :
2019

Abstract

This paper focuses on the development of the water-cooled divertor target concept known as Thermal Break, which was carried out in two phases. In Phase 1, six small scale mock-ups were fabricated and subjected to high heat flux (HHF) testing of up to 25 MW/m2 and thermal cycling of up to 500 cycles at 20 MW/m2. All six mock-ups survived the campaign and maintained 20 MW/m2 heat exhaust capability. Detailed examination of mock-ups was carried out to understand the damage mechanisms. One mock-up, which was tested beyond its design intent at 500 cycles, shows signs of progressive damage. Potential damage modes were identified and influenced subsequent Phase 2 mock-up design. Although there are signs of tungsten surface cracking, the predominant damage mode is not by "deep cracking" but substantial permanent deformation in the interlayer features. Therefore, in Phase 2 the manufacturing procedure was updated, the interlayer grooves were given stress-relieving radii which have significantly reduced the interlayer plastic strain range. Interlayer design parameters were selected following the use of response surface-based design search and optimization. Mock-ups of the Phase 2 design have been manufactured and HHF testing is planned within 2018. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09203796
Volume :
146
Database :
Academic Search Index
Journal :
Fusion Engineering & Design
Publication Type :
Academic Journal
Accession number :
138692750
Full Text :
https://doi.org/10.1016/j.fusengdes.2019.03.010