Prognostic value of vasoactive-inotropic score following continuous flow left ventricular assist device implantation.
- Source :
-
Journal of Heart & Lung Transplantation . Sep2019, Vol. 38 Issue 9, p930-938. 9p. - Publication Year :
- 2019
-
Abstract
- The purpose of this study is to evaluate the utility of vasoactive-inotropic score (VIS) in predicting outcomes after left ventricular assist device (LVAD) implantation and explore possible mechanisms of post-operative hemodynamic instability. Retrospective review was performed in 418 consecutive patients with LVAD implantation. VIS was calculated as dopamine + dobutamine + 10 × milrinone + 100 × epinephrine + 100 × norepinephrine (all μg/kg/min) + 10000 × vasopressin (U/kg/min) after initial stabilization in the operating room and upon arrival at the intensive care unit. The primary outcome was in-hospital mortality. The secondary outcomes were a composite of in-hospital mortality, delayed right ventricular assist device (RVAD) implantation, and continuous renal replacement therapy. The pre-operative biomarkers of inflammation, oxidative stress, endotoxemia and gut-derived metabolite trimethylamine-N-oxide (TMAO) were measured in a subset of 61 patients. Median VIS was 20.0 (interquartile range 13.3–27.9). VIS was an independent predictor of in-hospital mortality (odds ratio [OR] 1.06, 95% confidence interval [CI] 1.03–1.09, p < 0.001) and composite outcome (OR 1.03, 95% CI 1.01–1.06, p = 0.008). In-hospital mortality increased for each VIS quartile (0% vs 3.9% vs 7.6% vs 12.3%, p = 0.002). VIS was superior to other established LVAD risk models as a predictor of in-hospital mortality (area under the curve 0.73, 95% CI 0.64–0.82). The optimal cut-off point for VIS as a predictor of in-hospital mortality was 20. Pre-operative hemoglobin level was the only independent predictor of VIS ≥ 20 (p = 0.003). Patients with a high VIS were more likely to have elevated TMAO pre-operatively (53.6% vs 25.8%, p = 0.03). A high post-operative VIS is associated with adverse in-hospital outcomes and is a better predictor of in-hospital mortality compared with existing LVAD risk models. Whether early hemodynamic stabilization using RVAD may benefit patients with a high VIS remains to be investigated. [ABSTRACT FROM AUTHOR]
- Subjects :
- *HEART assist devices
*HOSPITAL mortality
*INTENSIVE care units
*OPERATING rooms
Subjects
Details
- Language :
- English
- ISSN :
- 10532498
- Volume :
- 38
- Issue :
- 9
- Database :
- Academic Search Index
- Journal :
- Journal of Heart & Lung Transplantation
- Publication Type :
- Academic Journal
- Accession number :
- 138459320
- Full Text :
- https://doi.org/10.1016/j.healun.2019.05.007