Back to Search Start Over

Simultaneous 13N-Ammonia and gadolinium first-pass myocardial perfusion with quantitative hybrid PET-MR imaging: a phantom and clinical feasibility study.

Authors :
Nazir, Muhummad Sohaib
Gould, Sarah-May
Milidonis, Xenios
Reyes, Eliana
Ismail, Tevfik F.
Neji, Radhouene
Roujol, Sébastien
O'Doherty, Jim
Xue, Hui
Barrington, Sally F.
Schaeffter, Tobias
Razavi, Reza
Marsden, Paul
Kellman, Peter
Plein, Sven
Chiribiri, Amedeo
Source :
European Journal of Hybrid Imaging. 9/3/2019, Vol. 3 Issue 1, pN.PAG-N.PAG. 1p.
Publication Year :
2019

Abstract

Background: Positron emission tomography (PET) is the non-invasive reference standard for myocardial blood flow (MBF) quantification. Hybrid PET-MR allows simultaneous PET and cardiac magnetic resonance (CMR) acquisition under identical experimental and physiological conditions. This study aimed to determine feasibility of simultaneous 13N-Ammonia PET and dynamic contrast-enhanced CMR MBF quantification in phantoms and healthy volunteers. Methods: Images were acquired using a 3T hybrid PET-MR scanner. Phantom study: MBF was simulated at different physiological perfusion rates and a protocol for simultaneous PET-MR perfusion imaging was developed. Volunteer study: five healthy volunteers underwent adenosine stress. 13N-Ammonia and gadolinium were administered simultaneously. PET list mode data was reconstructed using ordered subset expectation maximisation. CMR MBF was quantified using Fermi function-constrained deconvolution of arterial input function and myocardial signal. PET MBF was obtained using a one-tissue compartment model and image-derived input function. Results: Phantom study: PET and CMR MBF measurements demonstrated high repeatability with intraclass coefficients 0.98 and 0.99, respectively. There was high correlation between PET and CMR MBF (r = 0.98, p < 0.001) and good agreement (bias − 0.85 mL/g/min; 95% limits of agreement 0.29 to − 1.98). Volunteer study: Mean global stress MBF for CMR and PET were 2.58 ± 0.11 and 2.60 ± 0.47 mL/g/min respectively. On a per territory basis, there was moderate correlation (r = 0.63, p = 0.03) and agreement (bias − 0.34 mL/g/min; 95% limits of agreement 0.49 to − 1.18). Conclusion: Simultaneous MBF quantification using hybrid PET-MR imaging is feasible with high test repeatability and good to moderate agreement between PET and CMR. Future studies in coronary artery disease patients may allow cross-validation of techniques. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
25103636
Volume :
3
Issue :
1
Database :
Academic Search Index
Journal :
European Journal of Hybrid Imaging
Publication Type :
Academic Journal
Accession number :
138395829
Full Text :
https://doi.org/10.1186/s41824-019-0062-6