Back to Search Start Over

Development and evaluation of novel bio-safe filter paper-based kits for sputum microscopy and transport to directly detect Mycobacterium tuberculosis and associated drug resistance.

Authors :
Anthwal, Divya
Lavania, Surabhi
Gupta, Rakesh Kumar
Verma, Ajoy
Myneedu, Vithal Prasad
Sharma, Prem Prakash
Verma, Hitesh
Malhotra, Viveksheel
Gupta, Ashawant
Gupta, Nalini Kant
Sarin, Rohit
Haldar, Sagarika
Tyagi, Jaya Sivaswami
Source :
PLoS ONE. 8/13/2019, Vol. 14 Issue 8, p1-21. 21p.
Publication Year :
2019

Abstract

India has the highest burden of Tuberculosis (TB) and multidrug-resistant TB (MDR-TB) worldwide. Innovative technology is the need of the hour to identify these cases that remain either undiagnosed or inadequately diagnosed due to the unavailability of appropriate tools at primary healthcare settings. We developed and evaluated 3 kits, namely ‘TB Detect’ (containing BioFM-Filter device), ‘TB Concentration and Transport’ (containing Trans-Filter device) and ‘TB DNA Extraction’ kits. These kits enable bio-safe equipment-free concentration of sputum on filters and improved fluorescence microscopy at primary healthcare centres, ambient temperature transport of dried inactivated sputum filters to central laboratories and molecular detection of drug resistance by PCR and DNA sequencing (Mol-DST). In a 2-site evaluation (n = 1190 sputum specimens) on presumptive TB patients, BioFM-Filter smear exhibited a significant increase in positivity of 7% and 4% over ZN smear and LED-FM smear (p<0.05), respectively and an increment in smear grade status (1+ or 2+ to 3+) of 16% over ZN smear and 20% over LED-FM smear. The sensitivity of Mol-DST in presumptive MDR-TB and XDR-TB cases (n = 148) was 90% for Rifampicin (95% confidence interval [CI], 78–96%), 84% for Isoniazid (95% CI, 72–92%), 83% for Fluoroquinolones (95% CI, 66–93%) and 75% for Aminoglycosides (95% CI, 35–97%), using phenotypic DST as the reference standard. Test specificity was 88–93% and concordance was ~89–92% (κ value 0.8–0.9). The patient-friendly kits described here address several of the existing challenges and are designed to provide ‘Universal Access’ to rapid TB diagnosis, including drug-resistant disease. Their utility was demonstrated by application to sputum at 2 sites in India. Our findings pave the way for larger studies in different point-of-care settings, including high-density urban areas and remote geographical locations. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
8
Database :
Academic Search Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
138036953
Full Text :
https://doi.org/10.1371/journal.pone.0220967