Back to Search Start Over

AVALIAÇÃO CLÍNICA E HISTOLÓGICA DAS REAÇÕES TECIDUAIS PRODUZIDAS POR DIFERENTES IMPLANTES DA ABRAÇADEIRA AUTOESTÁTICA DE NÁILON EM RATOS WISTAR.

Authors :
Charas Santos, Ivan Felismino
Lopez Castañeda, Brayan Sayed
Rodríguez, Nathalia N.
de Siqueira Silva Júnior, José Ivaldo
Manea Ferreira, Gustavo
Martins Silva, Bruna
Tolffo Loibl, Louise
Source :
Archives of Veterinary Science. 2019, Vol. 24 Issue 2, p11-22. 12p.
Publication Year :
2019

Abstract

the aim of this study was to evaluate clinically and histological thetissue reactions produced by the implantation of the nylon cable tie transparent and colored in Wistar rats. Wistar male Wistar rats, aged 16 weeks, and weight between 350 and 450 grams were used. The rats were allocated in two groups of 24 animals: Group 1 - rats submitted to the implantation of the monofilament surgical nylon suture (Control Group); Group 2 - rats submitted to the implant of fragment of the transparent and colored nylon cable tie (Experimental Group). The implants of the animals of control group were performed with 5 mm of nylon suture monofilamentarbetween the carnosus and left paravertebral muscle; and 5 mm fragment were implanted in animal of experimental group of the transparent and colored nylon cable tie in the same region on opposite sides and equidistant from the spine. Eight rats from each group underwent euthanasia to perform the excisional biopsy of the implants for posterior histological examination in three moments: seventh day, 15th day and 90th day after implantation. Infection and / or inflammation evaluation was performed every 24 hours. Multifocal circumscribed lesions around the three implants were observed in 46.7% of the rats, between the first and seventh day after implantation. Acute inflammatory reaction was absent in all groups at the moments evaluated. Chronic inflammatory reaction was observed in the suture group and the clamps at all moments of evaluation except on the seventh day after the implantation in the group of transparent nylon cable tie. Mixed inflammatory reaction was observed in the suture group and the clamp bands on the seventh and 15th day. The implants of monofilament surgical nylon suture (Control Group), transparent and colored nylon cable tie (Experimental Group) showed similar macroscopic (clinical) and histological reactions in Wistar rats in a period of 90 days. [ABSTRACT FROM AUTHOR]

Details

Language :
Portuguese
ISSN :
1517784X
Volume :
24
Issue :
2
Database :
Academic Search Index
Journal :
Archives of Veterinary Science
Publication Type :
Academic Journal
Accession number :
137805095