Back to Search Start Over

Numerical simulation on NOX emissions in a municipal solid waste incinerator.

Authors :
Hu, Zhifeng
Jiang, Enchen
Ma, Xiaoqian
Source :
Journal of Cleaner Production. Oct2019, Vol. 233, p650-664. 15p.
Publication Year :
2019

Abstract

The simulations of combustion and NO X emissions process are conducted by computational fluid dynamics method with comprehensive physical and chemical models in a municipal solid waste incinerator. This study focused on the effects of primary NO X control methods (different loads, over fire air, the ratios of secondary air and over fire air) and secondary NO X control methods (selective non-catalytic reduction process) on NO X emission and combustion characteristic. Results showed that the moisture evaporation rate, volatile release rate, char burning rate, temperature and the strength of flow velocity decreased as decreasing the operating load. However, the NO X emission of furnace outlet increased from 273.18 mg/Nm3 to 602.10 mg/Nm3. 100% operating load was the best condition to obtain a lowest NO X emission and a best combustion characteristic among different loads. In addition, the combustion strategy combining secondary air and over fire air could improve the combustion performance and reduce NO X emission. Further, a higher over fire air ratio was conducive to the formation of strong swirl flow and the enhancement of flow velocity strength in the flue. The optimal over fire air ratio was 31%–35% with NO X emission of 267.05 mg/Nm3 to 273.18 mg/Nm3 and residence time of 2.75 s–3.03 s. Moreover, ammonia based selective non-catalytic reduction process, better than urea, achieved a NO X emission of 132.41 mg/Nm3, a NO X removal efficiency of 51.50% and NH 3 slip of 11.08 mg/Nm3 or 6.71 ppm. The study indicated that the optimal NO X control method was a condition of 100% load, combining with over fire air and 31% and 35% over fire air ratio. Moreover, the best secondary NO X control method was the ammonia based selective non-catalytic reduction process. • The NO X emission of furnace outlet increased as decreasing the operating load. • Operating load, OFA, OFA ratio and SNCR did have an impact on flow velocity strength. • OFA affected the combustion characteristics and NO X emission. • The optimal OFA ratio was 31%–35% with NO X emission of 267.05–273.18 mg/Nm3. • Ammonia based SNCR, with a NO X removal efficiency of 51.50%, was better than urea. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09596526
Volume :
233
Database :
Academic Search Index
Journal :
Journal of Cleaner Production
Publication Type :
Academic Journal
Accession number :
137475721
Full Text :
https://doi.org/10.1016/j.jclepro.2019.06.127