Power Control of Coupled Nonequilibrium Disk MHD Generator and Line-Commutated Inverter System.

Authors :
Inui, Yoshitaka
Ishikawa, Motoo
Umoto, Juro
Source :
Electrical Engineering in Japan. 2/1/1996, Vol. 116 Issue 2, p52-62. 11p.
Publication Year :
1996

Abstract

A new power control method is proposed which is suitable for the MHD power generation system which consists of nonequilibrium disk generator and line-commutated inverter. The thermal input of the generator is controlled by changing the inlet stagnation pressure, whereas the seed mass flow rate instead of the inlet stagnation pressure is utilized as a manipulated variable of power control system. It is possible that the proposed method can realize both high performance for part load operation and fast output power control of which the time constant is much shorter than the response time of thermal input. Numerical simulations are carried out for the MHD power generation system connected to infinite bus and then it is confirmed that the system is stable and shows excellent power control performance. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
04247760
Volume :
116
Issue :
2
Database :
Academic Search Index
Journal :
Electrical Engineering in Japan
Publication Type :
Academic Journal
Accession number :
13713379
Full Text :
https://doi.org/10.1002/eej.4391160205