Back to Search
Start Over
Macromolecular relaxation, strain, and extensibility determine elastocapillary thinning and extensional viscosity of polymer solutions.
- Source :
-
Proceedings of the National Academy of Sciences of the United States of America . 4/30/2019, Vol. 116 Issue 18, p8766-8774. 9p. - Publication Year :
- 2019
-
Abstract
- Delayed capillary break-up of viscoelastic filaments presents scientific and technical challenges relevant for drop formation, dispensing, and adhesion in industrial and biological applications. The flow kinematics are primarily dictated by the viscoelastic stresses contributed by the polymers that are stretched and oriented in a strong extensional flow field resulting from the streamwise gradients created by the capillarity-driven squeeze flow. After an initial inertiocapillary (IC) or viscocapillary (VC) regime, where elastic effects seem to play no role, the interplay of capillarity and viscoelasticity can lead to an elastocapillary (EC) response characterized by exponentially-slow thinning of neck radius (extensional relaxation time is determined from the delay constant). Less frequently, a terminal visco-elastocapillary (TVEC) response with linear decay in radius can be observed and used for measuring terminal, steady extensional viscosity. However, both IC/VC-EC and EC-TVEC transitions are inaccessible in devices that create stretched necks by applying a step strain to a liquid bridge (e.g., capillary breakup extensional rheometer). In this study, we use dripping-onto-substrate rheometry to obtain radius evolution data for unentangled polymer solutions. We deduce that the plots of transient extensional viscosity vs. Hencky strain (scaled by the respective values at the EC-TVEC transition) emulate the functional form of the birefringence-macromolecular strain relationship based on Peterlin's theory. We quantify the duration and strain between the IC/VC-EC and the EC-TVEC transitions using measures we term elastocapillary span and elastocapillary strain increment and find both measures show values directly correlated with the corresponding variation in extensional relaxation time. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00278424
- Volume :
- 116
- Issue :
- 18
- Database :
- Academic Search Index
- Journal :
- Proceedings of the National Academy of Sciences of the United States of America
- Publication Type :
- Academic Journal
- Accession number :
- 136214411
- Full Text :
- https://doi.org/10.1073/pnas.1820277116