Back to Search
Start Over
Influence of the flanges width and thickness on the shear strength of reinforced concrete beams with T-shaped cross section.
- Source :
-
Engineering Structures . Jun2019, Vol. 188, p506-518. 13p. - Publication Year :
- 2019
-
Abstract
- Highlights • Only web contribution to shear is considered in codes for design of T-section concrete beams. • Experimental testing shows that contribution to shear strength of flanges is not negligible. • This effect may drive to considerable cost savings in new structures. • This effect may become decisive when evaluating the shear capacity of existing structures. • An experimental and parametric numerical study of T-Beams failing in shear is presented. Abstract Shear design of reinforced concrete beams with T section considers only the contribution of the web, mainly provided by aggregate interlock. However, as the load increases and large web crack openings take place, aggregate interlock reduces and shear stresses tend to concentrate near the neutral axis, usually located in the flanges of T beams, whose contribution to shear strength may be not negligible, as it has been experimentally observed. Thus, the contribution of flanges may drive to considerable cost savings in new structures and may become decisive when evaluating the shear capacity of existing structures. To quantify such contribution, a nonlinear 3D-FEA model has been developed and calibrated with the results of shear tests performed on RC T-beams by the authors. Once adjusted, the model has been used to analyze the shear response of beams with different geometry and longitudinal reinforcement, usual in practice. It has been found that, up to certain limits, the contribution of the flanges to the shear strength increases as the amount of longitudinal reinforcement decreases, as the flanges width increases and as the flange thickness increases. The maximum contribution of flanges found in the present study is 31.3% of the total shear resisted. Furthermore, the numerical model has been used to visualize and quantify aspects that are not easy to obtain experimentally, such as the distribution of the shear stresses between the web and the flanges. The present study will contribute to derive a design expression for the shear effective flanges width of T beams. [ABSTRACT FROM AUTHOR]
- Subjects :
- *CONCRETE beams
*SHEAR strength
*FLANGES
*SHEARING force
Subjects
Details
- Language :
- English
- ISSN :
- 01410296
- Volume :
- 188
- Database :
- Academic Search Index
- Journal :
- Engineering Structures
- Publication Type :
- Academic Journal
- Accession number :
- 135602761
- Full Text :
- https://doi.org/10.1016/j.engstruct.2019.03.057