Back to Search
Start Over
Impact of operating parameters on 80 K pulse tube cryocoolers for space applications.
- Source :
-
International Journal of Refrigeration . Mar2019, Vol. 99, p226-233. 8p. - Publication Year :
- 2019
-
Abstract
- Highlights • The impacts of operating parameters on PTC were analyzed. • The effects of frequencies and average pressures on the regenerator and the phase shifter were simulated. • The pressure ratio, the waveforms, the motor efficiency, and the cooling capacity were experimental studied. • A cooling power of 10 W/80 K with 171 W input power can be achieved by optimizing the operating parameters. Abstract Pulse tube cryocoolers (PTCs) represent a significant enabling technology for infrared detectors in space applications. A PTC can be efficiently operated by optimizing the structural parameters and impedance characteristics among different components. While the structures of the components are determined, the operating parameters are the most effective and simple methods to optimize the cooling performance of a PTC. The regenerator losses (regenerative losses, heat conduction losses and pressure drop losses) and the phase shifting ability (phase angle) are affected by the operating parameters. Based on theoretical and simulated analysis, the effects of operating parameters on the linear motor, regenerator and phase shifter are investigated. The pressure ratio, waveforms of the pressure and displacement, phase angle, motor efficiency, input power and cooling capacity are then presented by an experiment to clarify the influence mechanism. The pressure ratio and phase characteristics at the entrances of the regenerator and inertance tube are changed with different operating parameters. Corresponding with the piston displacement and motor efficiency, there is an optimal average pressure for the best cooling efficiency. The results show that a high compressor efficiency of 88% and a relative Carnot efficiency (rCOP) of 16.08% is achieved at 2.5 MPa and 51 Hz, while a relative Carnot efficiency of 16.0% is achieved at 3.5 MPa and 52 Hz by optimizing the frequency and pressure. [ABSTRACT FROM AUTHOR]
- Subjects :
- *TUBES
*SPACE
*HEAT conduction
*INFRARED detectors
*PHASE shifters
Subjects
Details
- Language :
- English
- ISSN :
- 01407007
- Volume :
- 99
- Database :
- Academic Search Index
- Journal :
- International Journal of Refrigeration
- Publication Type :
- Academic Journal
- Accession number :
- 135352598
- Full Text :
- https://doi.org/10.1016/j.ijrefrig.2018.12.026