Back to Search Start Over

Electrochemical sensor based on molecularly imprinted poly(ortho-phenylenediamine) for determination of hexahydrofarnesol in aviation biokerosene.

Authors :
Buffon, Edervaldo
Stradiotto, Nelson Ramos
Source :
Sensors & Actuators B: Chemical. May2019, Vol. 287, p371-379. 9p.
Publication Year :
2019

Abstract

Graphical abstract Highlights • Hexahydrofarnesol is the main contaminant of aviation biokerosene. • The determination of hexahydrofarnesol is of great importance for the aviation and biokerosene industries. • The first electrochemical sensor for the determination of hexahydrofarnesol was developed in this work. • The first electroanalytical method for the analysis of aviation biokerosene was proposed. Abstract In this work, the first electrochemical sensor for determination of hexahydrofarnesol in aviation biokerosene was developed by electropolymerization of a molecularly imprinted ortho-phenylenediamine film on a glassy carbon electrode. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, RAMAN spectroscopy and atomic force microscopy. Parameters that influence the performance of the imprinted sensor, such as the molar ratio between functional monomer and template molecule, number of cycles and pH used in the electropolymerization, extraction time of the template molecule, and time of rebinding of the hexahydrofarnesol molecules in the imprinted cavities were optimized. The developed sensor presented the following linear ranges: 4.0 × 10−8 to 1.5 × 10-7 mol L-1 and 1.5 × 10-7 to 1.5 × 10-6 mol L-1. The apparent dissociation constant (K D) for the first linear range of this device calculated by the isothermal Langmuir adsorption model was 4.8 × 10-7 mol L-1. The limit of detection, limit of quantification and sensitivity were 1.2 × 10−8 mol L-1, 4.1 × 10−8 mol L-1 and 67 A L mol-1 (n = 3) respectively. The sensor showed considerable inter-day and intra-day repeatability, with RSD values ≤ 4.8%, and had 96% of its initial current preserved after being stored for 10 days in contact with air at room temperature. The developed method was successfully applied toward the determination of hexahydrofarnesol in aviation biokerosene. Mean recoveries ranged from 97.6% to 105.8%, with RSDs within the interval of 1.7% to 3.9%. These results indicate that the method developed has a good accuracy for the determination of hexahydrofarnesol. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09254005
Volume :
287
Database :
Academic Search Index
Journal :
Sensors & Actuators B: Chemical
Publication Type :
Academic Journal
Accession number :
135351339
Full Text :
https://doi.org/10.1016/j.snb.2019.02.059