Back to Search Start Over

Realization and performance assessment of a force-sensing based smart floor panel for indoor localization applications.

Authors :
Cheng, Chung-Hao
Wu, Ming-Feng
Guo, Shu-Heng
Chen, Kuo-Shen
Source :
Sensors & Actuators A: Physical. Jan2019, Vol. 285, p468-481. 14p.
Publication Year :
2019

Abstract

Graphical abstract Highlights • A force-sensing based floor panel is designed for indoor localization applications. • Corresponding localization algorithms and calibration schemes are designed and realized. • Positioning accuracy can be up to ±1 cm over a 1 m span. • Demos in robot localizations, center of gravity measurement, and data fusion are done for promoting applications. Abstract Accurate position detection of indoor objects is crucial for many intelligent life applications and can be realized by various approaches. In certain applications, indoor position detection can be performed using some forms of touch-based floor sensing systems to avoid problems faced by using vision or inertial navigation approaches. The present study develops a floor panel test stage (1 × 1 m2) and its associated localization schemes based on rigid body statics for evaluating the feasibility and the positioning performance on determining the indoor locations of moving objects such as mobile robots. The motion signals are detected by four load cells located at the panel corners and are used to determine the position of the applied forces by means of rigid body statics. Essential tests are performed to examine the system performance. Noticed that due to the existence of boundary reaction moments, traditional predictions based on rigid body statics may not be sufficient and a calibration procedure is required. In parallel, for accommodating different possible scenarios, the corresponding associated localization schemes for estimating the force-applied locations based on the readout history and algorithms are also proposed and realized. The results indicate that the localization accuracy is approximately ± 1 cm over a 1 m span after calibration. Although the method is essentially static, it can still detect object motion provided the motion frequency less than 2 Hz. Furthermore, demonstrations are also presented to highlight other possible applications such as center of gravity measurement of objects and the fusion of multiple localization schemes in indoor environment. Finally, an indoor localization demonstration based on both wiimote IR LED and this smart floor is presented to elucidate the possible application of this work in sensor fusion for indoor motion control. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09244247
Volume :
285
Database :
Academic Search Index
Journal :
Sensors & Actuators A: Physical
Publication Type :
Academic Journal
Accession number :
133787577
Full Text :
https://doi.org/10.1016/j.sna.2018.11.047