Phakic refractive lens implantation in high myopic patients: One-year results

Authors :
Pallikaris, Ioannis G.
Kalyvianaki, Maria I.
Kymionis, George D.
Panagopoulou, Sophia I.
Source :
Journal of Cataract & Refractive Surgery. Jun2004, Vol. 30 Issue 6, p1190-1197. 8p.
Publication Year :
2004

Abstract

Purpose: To evaluate the efficacy and safety of implantation of a new posterior chamber phakic refractive lens (PRL, Ciba Vision Surgical) in highly myopic eyes.Setting: Department of Ophthalmology, Medical School, University of Crete, Vardinoyannion Eye Institute of Crete, Crete, Greece.Methods: Thirty-four myopic eyes of 19 patients were treated for high myopia with implantation of a silicone PRL in the posterior chamber. Mean patient age was 29.0 years ± 7.9 (SD) (range 18 to 44 years). Manifest refraction in spherical equivalent (MR), uncorrected (UCVA) and best corrected (BCVA) visual acuity (decimal scale), intraocular pressure, higher-order aberrations (root-mean-square [RMS] wavefront error measured with a Shack-Hartmann wavefront sensor WASCA analyzer [Carl Zeiss, Meditec]), possible complications, and subjective symptoms were evaluated.Results: Phakic refractive lenses were successfully implanted in all eyes. Mean follow-up was 17.17 ± 3.76 months (range 12 to 24 months). There was a statistically significant reduction in the MR (from -14.70 D ± 2.65 D [range -20.75 D to -10.50 D] to -0.61 D ± 0.89 D [range -2.25 D to 1.00 D]) (P<.001). Twenty-seven (79%) and 15 eyes (44%) were within ±1.00 D and ±0.50 D of target refraction, respectively. Mean UCVA significantly improved (from counting fingers to 0.62 ± 0.28 (range 0.08 to 1.20) (P<.001). Mean BCVA also improved from 0.70 ± 0.24 (range 0.10 to 1.00) to 0.85 ± 0.24 (range 0.10 to 1.20) (P<0.001). Overall, there was a mean increase in BCVA of 1.5 ± 1.5 lines (range loss of 2 lines to gain of 5 lines). There was no statistically significant difference in higher-order aberrations after PRL implantation (pre-PRL RMS: 0.18 μm ± 0.08 μm [range 0.09 μm to 0.38 μm]; post-PRL RMS: 0.21 μm ± 0.08 μm; [range 0.05 μm to 0.38 μm]) (P = .12).Conclusion: The PRL showed encouraging results in treating high myopia. Additional patients and longer follow-up period are needed to detect the long-term efficacy and safety of this refractive lens. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
08863350
Volume :
30
Issue :
6
Database :
Academic Search Index
Journal :
Journal of Cataract & Refractive Surgery
Publication Type :
Academic Journal
Accession number :
13330749
Full Text :
https://doi.org/10.1016/j.jcrs.2003.10.039