Investigation on Potential-Induced Degradation in a 50 MWp Crystalline Silicon Photovoltaic Power Plant.

Authors :
Huang, Jingsheng
Li, Hongtao
Sun, Yaojie
Wang, He
Yang, Hong
Source :
International Journal of Photoenergy. 10/28/2018, p1-7. 7p.
Publication Year :
2018

Abstract

The regular performance deterioration of P-type crystalline silicon solar modules and module strings caused by potential-induced degradation in a photovoltaic power plant was found in the field. The PID-affected solar modules dismounted from the photovoltaic power plant were further investigated systematically in the laboratory. For the first time, we found that the neutral point of voltage in a module string moved forward to the positive pole for a PID-affected module string as time goes on. Even if low positive voltage is applied to a PID-prone module, it could cause PID. The thermographic and electroluminescence (EL) images of a PID-affected module string also exhibit a regular degradation pattern. This is in good agreement with the measured power loss of the dismounted solar modules under standard test conditions. The results obtained in this paper show that the maximum power degradation rate of solar modules was as high as 53.26% after only one year of operation because of PID in the field. Due to the vast amount of solar modules and incomplete recovery, this is a terrible catastrophe for the owner of a power plant and module producer. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1110662X
Database :
Academic Search Index
Journal :
International Journal of Photoenergy
Publication Type :
Academic Journal
Accession number :
132650830
Full Text :
https://doi.org/10.1155/2018/3286124