Back to Search Start Over

Rheological Tests with a Boger Fluid and a Rough Geometry.

Authors :
Paduano, Liana Pasqualina
Caserta, Sergio
Minale, Mario
Carotenuto, Claudia
Source :
AIP Conference Proceedings. 2018, Vol. 1981 Issue 1, p020095-1-020095-4. 4p. 1 Diagram, 3 Graphs.
Publication Year :
2018

Abstract

In rheometry rough geometries are often used to prevent wall-slip typically encountered with heterogeneous fluids. However, the fluid does not stand still within the geometry roughness and a residual wall-slip can be often measured. The problem can be treated as the flow through a porous medium that is here investigated when the fluid is non-Newtonian. We use a Boger fluid that is a good model for the Second Order Fluids and a commercial cross-hatched plate as rough geometry. The results obtained are in good qualitative agreement with predictions available in the literature and are promising for the development of a simple procedure to use rough geometries with viscoelastic fluids. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
1981
Issue :
1
Database :
Academic Search Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
130715328
Full Text :
https://doi.org/10.1063/1.5045957