Back to Search Start Over

Adaptability of Closed Loop During Labor, Delivery, and Postpartum: A Secondary Analysis of Data from Two Randomized Crossover Trials in Type 1 Diabetes Pregnancy.

Authors :
Stewart, Zoe A.
Yamamoto, Jennifer M.
Wilinska, Malgorzata E.
Hartnell, Sarah
Farrington, Conor
Hovorka, Roman
Murphy, Helen R.
Source :
Diabetes Technology & Therapeutics. Jul2018, Vol. 20 Issue 7, p501-505. 5p.
Publication Year :
2018

Abstract

Tight glucose control during labor and delivery is recommended for pregnant women with type 1 diabetes. This can be challenging to achieve using the current treatment modalities. The automated nature of closed loop and its ability to adapt to real-time glucose levels make it well suited for use during labor, delivery, and the immediate postpartum period. We report observational data of participants from two randomized crossover trials who chose to continue using closed loop during labor, delivery, and postpartum. Labor was defined as the 24 h before delivery and postpartum as the 48 h after delivery. The glucose target range during pregnancy was 3.5-7.8 mmol/L (63-140 mg/dL) and 3.9-10 mmol/L (70-180 mg/dL) after delivery. Twenty-seven (84.4%) of the potential 32 trial participants used closed loop through labor, delivery, and postpartum. Use of closed loop was associated with 82.0% (interquartile range [IQR] 49.3, 93.0) time-in-target range during labor and delivery and a mean glucose of 6.9 ± 1.4 mmol/L (124 ± 25 mg/dL). Closed loop performed well throughout vaginal, elective, and emergency cesarean section deliveries. Postpartum, women spent 83.3% (IQR 75.2, 94.6) time-in-target range (3.9-10.0 mmol/L [70-180 mg/dL]), with a mean glucose of 7.2 ± 1.4 mmol/L (130 ± 25 mg/dL). There was no difference in maternal glucose concentration between mothers of infants with and without neonatal hypoglycemia (6.9 ± 1.6 mmol/L and 6.8 ± 1.1 mmol/L [124 ± 29 mg/dL and 122 ± 20 mg/dL] respectively; P = 0.84). Automated closed-loop insulin delivery is feasible during hospital admissions for labor, delivery, and postpartum. Larger scale studies are needed to evaluate its efficacy compared with current clinical approaches as well as understand how women and healthcare providers will adopt this technology. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15209156
Volume :
20
Issue :
7
Database :
Academic Search Index
Journal :
Diabetes Technology & Therapeutics
Publication Type :
Academic Journal
Accession number :
130410245
Full Text :
https://doi.org/10.1089/dia.2018.0060