Back to Search Start Over

Flupirtine Determination in Human Blood Plasma by HPLC with Mass-Spectrometric Detection and its Application to Pharmacokinetic Studies.

Authors :
Krasnykh, L. M.
Rodina, T. A.
Mel’nikov, E. S.
Vasilenko, G. F.
Smirnov, V. V.
Sokolov, A. V.
Arkhipov, V. V.
Source :
Pharmaceutical Chemistry Journal. Mar2018, Vol. 51 Issue 12, p1123-1128. 6p.
Publication Year :
2018

Abstract

A validated method for quantitative determination of flupirtine in human blood plasma using liquid chromatography combined with tandem mass spectrometry (HPLC-MS/MS) was proposed. Biological samples were prepared by precipitating proteins using MeOH. The chromatographic separation used a Zorbax Eclipse Plus C18 column with gradient elution. A Shimadzu 8040 triple quadrupole mass spectrometer in multiple-reaction-monitoring mode (+MRM) with chemical ionization at atmospheric pressure (APCI) was used to determine the molecular ion of flupirtine with m/z 305.2. Acalibration curve for flupirtine was linear (R = 0.994) in the concentration range 25 - 2,500 ng/mL with a lower detection limit of 25 ng/mL. Validation of the method indicated that it was highly sensitive, specific, accurate, and precise and that the analyte was stable. The method was successfully applied to comparative pharmacokinetic studies of drugs containing flupirtine. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0091150X
Volume :
51
Issue :
12
Database :
Academic Search Index
Journal :
Pharmaceutical Chemistry Journal
Publication Type :
Academic Journal
Accession number :
129652629
Full Text :
https://doi.org/10.1007/s11094-018-1752-2