Back to Search
Start Over
Modeling the effect of shunt current on the charge transfer efficiency of an all-vanadium redox flow battery.
- Source :
-
Journal of Power Sources . Jun2018, Vol. 390, p168-175. 8p. - Publication Year :
- 2018
-
Abstract
- In an all-vanadium redox flow battery (VRFB), a shunt current is inevitable owing to the electrically conductive electrolyte that fills the flow channels and manifolds connecting cells. The shunt current decreases the performance of a VRFB stack as well as the energy conversion efficiency of a VRFB system. To understand the shunt-current loss in a VRFB stack with various designs and operating conditions, a mathematical model is developed to investigate the effects of the shunt current on battery performance. The model is calibrated with experimental data under the same operating conditions. The effects of the battery design, including the number of cells, state of charge (SOC), operating current, and equivalent resistance of the electrolytes in the flow channels and manifolds, on the shunt current are analyzed and discussed. The charge-transfer efficiency is calculated to investigate the effects of the battery design parameters on the shunt current. When the cell number is increased from 5 to 40, the charge transfer efficiency is decreased from 0.99 to a range between 0.76 and 0.88, depending on operating current density. The charge transfer efficiency can be maintained at higher than 0.9 by limiting the cell number to less than 20. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 03787753
- Volume :
- 390
- Database :
- Academic Search Index
- Journal :
- Journal of Power Sources
- Publication Type :
- Academic Journal
- Accession number :
- 129626180
- Full Text :
- https://doi.org/10.1016/j.jpowsour.2018.04.042