Back to Search Start Over

Mechanical characterization of a pre-fabricated connection system for cross laminated timber structures in seismic regions.

Authors :
Polastri, A.
Giongo, I.
Angeli, A.
Brandner, R.
Source :
Engineering Structures. Jul2018, Vol. 167, p705-715. 11p.
Publication Year :
2018

Abstract

This paper focuses on the point-to-point X-RAD connection system for the construction of cross laminated timber buildings in earthquake prone areas. Tests on X-RAD connectors subjected to “shear-tension” and “shear-compression” loading configurations are presented as supplement to the experimental data provided in previously published research. Tests aimed at characterizing the behavior of timber walls assembled with the system and loaded by lateral force are also reported. A capacity domain that allows for quick safety checks for any given load combination on the connector was derived from the experimental outcomes and is presented herein. An extremely simplified, yet effective numerical approach (the connector behavior is reproduced by 3-link elements) is proposed and compared with the experimental evidence. The 3-link model was able to reproduce with sufficient accuracy both, the elastic and post-elastic response of the walls. In the discussion section, particular attention is given to the system capability of dissipating energy and exhibiting ductile behavior. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01410296
Volume :
167
Database :
Academic Search Index
Journal :
Engineering Structures
Publication Type :
Academic Journal
Accession number :
129589445
Full Text :
https://doi.org/10.1016/j.engstruct.2017.12.022