Back to Search Start Over

Comparative analysis of fixation and embedding techniques for optimized histological preparation of zebrafish.

Authors :
Copper, Jean E.
Budgeon, Lynn R.
Foutz, Christina A.
van Rossum, Damian B.
Vanselow, Daniel J.
Hubley, Margaret J.
Clark, Darin P.
Mandrell, David T.
Cheng, Keith C.
Source :
Comparative Biochemistry & Physiology Part C: Toxicology & Pharmacology. Jun2018, Vol. 208, p38-46. 9p.
Publication Year :
2018

Abstract

In recognition of the importance of zebrafish as a model organism for studying human disease, we have created zebrafish content for a web-based reference atlas of microanatomy for comparing histology and histopathology between model systems and with humans ( http://bio-atlas.psu.edu ). Fixation, decalcification, embedding, and sectioning of zebrafish were optimized to maximize section quality. A comparison of protocols involving six fixatives showed that 10% Neutral Buffered Formalin at 21 °C for 24 h yielded excellent results. Sectioning of juveniles and adults requires bone decalcification; EDTA at 0.35 M produced effective decalcification in 21-day-old juveniles through adults (≥~3 Months). To improve section plane consistency in sets of larvae, we have developed new array casting molds based on the outside contours of larvae derived from 3D microCT images. Tissue discontinuity in sections, a common barrier to creating quality sections of zebrafish, was minimized by processing and embedding the formalin-fixed zebrafish tissues in plasticized forms of paraffin wax, and by periodic hydration of the block surface in ice water between sets of sections. Optimal H&E (Hematoxylin and Eosin) staining was achieved through refinement of standard protocols. High quality slide scans produced from glass histology slides were digitally processed to maximize image quality, and experimental replicates posted as full slides as part of this publication. Modifications to tissue processing are still needed to eliminate the need for block surface hydration. The further addition of slide collections from other model systems and 3D tools for visualizing tissue architecture would greatly increase the utility of the digital atlas. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15320456
Volume :
208
Database :
Academic Search Index
Journal :
Comparative Biochemistry & Physiology Part C: Toxicology & Pharmacology
Publication Type :
Academic Journal
Accession number :
129403916
Full Text :
https://doi.org/10.1016/j.cbpc.2017.11.003