Back to Search Start Over

Pulse shape discrimination based on fast signals from silicon photomultipliers.

Authors :
Yu, Junhao
Wei, Zhiyong
Fang, Meihua
Zhang, Zixia
Cheng, Can
Wang, Yi
Su, Huiwen
Ran, Youquan
Zhu, Qingwei
Zhang, He
Duan, Kai
Chen, Ming
Liu, Meng
Source :
Nuclear Instruments & Methods in Physics Research Section A. Jun2018, Vol. 894, p129-137. 9p.
Publication Year :
2018

Abstract

Recent developments in organic plastic scintillators capable of pulse shape discrimination (PSD) enable a breakthrough in discrimination between neutrons and gammas. Plastic scintillator detectors coupled with silicon photomultipliers (SiPMs) offer many advantages, such as lower power consumption, smaller volume, and especially insensitivity to magnetic fields, compared with conventional photomultiplier tubes (PMTs). A SensL SiPM has two outputs: a standard output and a fast output. It is known that the charge injected into the fast output electrode is typically approximately 2% of the total charge generated during the avalanche, whereas the charge injected into the standard output electrode is nearly 98% of the total. Fast signals from SiPMs exhibit better performance in terms of timing and time-correlated measurements compared with standard signals. The pulse duration of a standard signal is on the order of hundreds of nanoseconds, whereas the pulse duration of the main monopole waveform of a fast signal is a few tens of nanoseconds. Fast signals are traditionally thought to be suitable for photon counting at very high speeds but unsuitable for PSD due to the partial charge collection. Meanwhile, the standard outputs of SiPMs coupled with discriminating scintillators have yielded nice PSD performances, but there have been no reports on PSD using fast signals. Our analysis shows that fast signals can also provide discrimination if the rate of charge injection into the fast output electrode is fixed for each event, even though only a portion of the charge is collected. In this work, we achieved successful PSD using fast signals; meanwhile, using a coincidence timing window of less 3 nanoseconds between the readouts from both ends of the detector reduced the influence of the high SiPM dark current. We experimentally achieved good timing performance and PSD capability simultaneously. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01689002
Volume :
894
Database :
Academic Search Index
Journal :
Nuclear Instruments & Methods in Physics Research Section A
Publication Type :
Academic Journal
Accession number :
129206212
Full Text :
https://doi.org/10.1016/j.nima.2018.03.010