Back to Search Start Over

The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study.

Authors :
Chubb, Henry
Karim, Rashed
Roujol, Sébastien
Nuñez-Garcia, Marta
Williams, Steven E.
Whitaker, John
Harrison, James
Butakoff, Constantine
Camara, Oscar
Chiribiri, Amedeo
Schaeffter, Tobias
Wright, Matthew
O’Neill, Mark
Razavi, Reza
Source :
Journal of Cardiovascular Magnetic Resonance (BioMed Central). 3/19/2018, Vol. 20, p1-15. 15p. 2 Color Photographs, 1 Diagram, 3 Charts, 4 Graphs.
Publication Year :
2018

Abstract

Background: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation. Methods: Forty subjects undergoing first time ablation for atrial fibrillation (AF) had detailed CMR assessment of PAAS. Following baseline pre-ablation scan, two scans (separated by 48 h) were performed at three months post-ablation. Each scan session included 3D LGE acquisition at 10, 20 and 30 min post administration of gadolinium-based contrast agent (GBCA). Subjects were allocated at second scan post-ablation to identical imaging parameters (‘Repro’, n = 10), 3 T scanner (‘3 T’, n = 10), half-slice thickness (‘Half-slice’, n = 10) or half GBCA dose (‘Half-gad’, n = 10). PAAS was compared to baseline scar and then reproducibility was assessed for two measures of thresholded scar (% left atrial (LA) occupied by PAAS (%LA PAAS) and Pulmonary Vein Encirclement (PVE)), and then four measures of non-thresholded scar (point-by-point assessment of PAAS, four normalisation methods). Thresholded measures of PAAS were evaluated against procedural outcome (AF recurrence). Results: A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. At 20 and 30 min, inter-scan reproducibility was good to excellent (coefficient of variation at 20 min and 30 min: %LA PAAS 0.41 and 0.20; PVE 0.13 and 0.04 respectively for ‘Repro’ group). Changes in imaging parameters, especially reduced GBCA dose, reduced interscan reproducibility, but for most measures remained good to excellent (ICC for %LA PAAS 0.454–0.825, PVE 0.618–0.809 at 30 min). For non-thresholded scar, highest reproducibility was observed using blood pool z-score normalisation technique: inter-scan ICC 0.759 (absolute agreement, ‘Repro’ group). There was no significant relationship between indices of PAAS and AF recurrence. Conclusion: PAAS imaging is a reproducible finding. Imaging should be performed at least 20 min post-GBCA injection, and a blood pool z-score should be considered for normalisation of signal intensities. The clinical implications of these findings remain to be established in the absence of a simple correlation with arrhythmia outcome. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1532429X
Volume :
20
Database :
Academic Search Index
Journal :
Journal of Cardiovascular Magnetic Resonance (BioMed Central)
Publication Type :
Academic Journal
Accession number :
128609270
Full Text :
https://doi.org/10.1186/s12968-018-0438-y