Early type A dissection with the aortic connector device
- Source :
-
European Journal of Cardio-Thoracic Surgery . May2004, Vol. 25 Issue 5, p902. 3p. - Publication Year :
- 2004
-
Abstract
- A 75-year-old woman who had suffered type B dissection had coronary artery bypass grafting surgery using a mechanical aortic connector. Four days after the operation, she had a sudden syncope. CT demonstrated type A dissection, and an emergency operation was done, and postoperative course was uneventful. This case demonstrates that this connector should be used carefully in patients with a history of type B dissection. [Copyright &y& Elsevier]