Magnetic Energy Difference Between Partial Inductance Method and Magnetic Field Intensity in Open-Loop Problems.

Authors :
Ni, Chouwei
Zhao, Zhibin
Cui, Xiang
Source :
IEEE Transactions on Electromagnetic Compatibility. Jun2018, Vol. 60 Issue 3, p803-806. 4p.
Publication Year :
2018

Abstract

Magnetic field energy could be calculated by means of inductance, magnetic field intensity, or vector potential A, respectively. However, the former two methods may not reach an agreement in open loop problems. Partial inductance is calculated through A, whereas magnetic field intensity is also related to A. This letter analytically derives the difference between the former two methods. It is necessary that displacement current have to be carefully considered in open loop problems. A numerical example is given out for validation. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
00189375
Volume :
60
Issue :
3
Database :
Academic Search Index
Journal :
IEEE Transactions on Electromagnetic Compatibility
Publication Type :
Academic Journal
Accession number :
127252535
Full Text :
https://doi.org/10.1109/TEMC.2017.2737468